Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
356
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0204 # 08 Y:1994 | 08 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $275 | $400 | Not Implemented |
ND0204 # 09 Y:1994 | 09 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $232 | $640 | Not Implemented |
ND0204 # 10 Y:1994 | 10 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $178 | $260 | Not Implemented |
ND0184 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,418 | $9,845 | Implemented |
ND0184 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,206 | $927 | Implemented |
ND0184 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,585 | $660 | Implemented |
ND0184 # 04 Y:1994 | 04 | 1994 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $567 | $375 | Not Implemented |
ND0184 # 05 Y:1994 | 05 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $317 | $580 | Not Implemented |
ND0184 # 06 Y:1994 | 06 | 1994 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $256 | $500 | Implemented |
ND0184 # 07 Y:1994 | 07 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $149 | $0 | Not Implemented |
ND0046 # 01 Y:1992 | 01 | 1992 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,760 | $14,000 | Not Implemented |
ND0046 # 02 Y:1992 | 02 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $582 | $4,765 | Implemented |
ND0046 # 03 Y:1992 | 03 | 1992 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $1,535 | $1,200 | Not Implemented |
ND0046 # 04 Y:1992 | 04 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $582 | $300 | Implemented |
ND0046 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38 | $500 | Implemented |
ND0046 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $104 | $269 | Implemented |
ND0046 # 07 Y:1992 | 07 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $62 | $200 | Not Implemented |
ND0018 # 01 Y:1992 | 01 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $21,576 | $62,547 | Not Implemented |
ND0018 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,520 | $0 | Not Implemented |
ND0018 # 03 Y:1992 | 03 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,149 | $400 | Not Implemented |
ND0018 # 04 Y:1992 | 04 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,895 | $0 | Not Implemented |
ND0018 # 05 Y:1992 | 05 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $149 | $200 | Not Implemented |
UD0326 # 01 Y:1990 | 01 | 1990 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,550 | $3,000 | Not Implemented |
UD0326 # 02 Y:1990 | 02 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,372 | $0 | Implemented |
UD0326 # 03 Y:1990 | 03 | 1990 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $3,745 | $0 | Not Implemented |