IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

15,265

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0420 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,406 $5,658 Implemented
OK0420 # 03 Y:1993 03 1993 RECOVER WASTE HEAT FROM EQUIPMENT $390 $1,000 Not Implemented
OK0420 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $289 $559 Implemented
UD0418 # 01 Y:1993 01 1993 PAY UTILITY BILLS ON TIME $2,115 $0 Not Implemented
UD0418 # 02 Y:1993 02 1993 OPTIMIZE PLANT POWER FACTOR $14,702 $9,250 Implemented
UD0418 # 03 Y:1993 03 1993 INSTALL EFFICIENT RECTIFIERS $1,456 $15,000 Implemented
UD0418 # 04 Y:1993 04 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,180 $4,000 Implemented
UD0418 # 05 Y:1993 05 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $31,259 $6,000 Implemented
UD0418 # 06 Y:1993 06 1993 RECOVER AND REUSE COOLING WATER $12,300 $1,000 Implemented
AR0012 # 01 Y:1993 01 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,665 $1,170 Implemented
AR0012 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,387 $400 Implemented
AR0012 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $949 $720 Implemented
AR0012 # 04 Y:1993 04 1993 OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS $1,373 $100 Not Implemented
AR0012 # 05 Y:1993 05 1993 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $23,430 $23,250 Not Implemented
AR0012 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $1,684 $330 Not Implemented
OK0415 # 01 Y:1993 01 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,868 $0 Not Implemented
OK0415 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,357 $4,918 Implemented
OK0415 # 03 Y:1993 03 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,487 $11,785 Implemented
OK0415 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,725 $3,693 Implemented
OK0415 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $948 $1,079 Implemented
OK0415 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $612 $749 Not Implemented
OK0415 # 07 Y:1993 07 1993 IMPROVE COMBUSTION CONTROL CAPABILITY $40,284 $190,000 Not Implemented
UF0075 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,641 $1,297 Implemented
UF0075 # 02 Y:1993 02 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,371 $1,401 Not Implemented
UF0075 # 03 Y:1993 03 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $172 $300 Implemented