Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,265
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0059 # 09 Y:1993 | 09 | 1993 | OPTIMIZE PLANT POWER FACTOR | $26,535 | $24,550 | Not Implemented |
OK0398 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,312 | $3,809 | Not Implemented |
OK0398 # 02 Y:1993 | 02 | 1993 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,494 | $898 | Implemented |
OK0398 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $864 | $0 | Implemented |
OK0398 # 04 Y:1993 | 04 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $779 | $1,600 | Implemented |
OK0398 # 05 Y:1993 | 05 | 1993 | INSULATE BARE EQUIPMENT | $238 | $527 | Not Implemented |
OK0398 # 06 Y:1993 | 06 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $179 | $217 | Not Implemented |
UD0396 # 01 Y:1993 | 01 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $71 | $15 | Implemented |
UD0396 # 02 Y:1993 | 02 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $745 | $700 | Implemented |
AM0174 # 01 Y:1993 | 01 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,460 | $0 | Not Implemented |
AM0174 # 02 Y:1993 | 02 | 1993 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,950 | $0 | Implemented |
AM0174 # 03 Y:1993 | 03 | 1993 | INSTALL FOSSIL FUEL MAKE-UP AIR UNIT | $890 | $460 | Implemented |
AM0174 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,720 | $420 | Implemented |
AM0174 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,370 | $0 | Implemented |
ME0102 # 01 Y:1993 | 01 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $486 | $90 | Not Implemented |
ME0102 # 02 Y:1993 | 02 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,485 | $8,690 | Not Implemented |
ME0102 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,038 | $7,200 | Implemented |
ME0102 # 04 Y:1993 | 04 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,674 | $1,400 | Implemented |
ME0102 # 05 Y:1993 | 05 | 1993 | OPTIMIZE PLANT POWER FACTOR | $1,363 | $0 | Not Implemented |
HO0043 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $832 | $1,403 | n/a |
HO0043 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,435 | $471 | n/a |
HO0043 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,290 | $1,893 | n/a |
HO0043 # 04 Y:1993 | 04 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $353 | $600 | n/a |
CO0267 # 01 Y:1993 | 01 | 1993 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,010 | $250 | Implemented |
CO0267 # 02 Y:1993 | 02 | 1993 | REDUCE VENTILATION AIR | $1,860 | $250 | Implemented |