Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,260
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0202 # 05 Y:1986 | 05 | 1986 | IMPROVE LUBRICATION PRACTICES | $568 | $100 | Implemented |
KU0202 # 06 Y:1986 | 06 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $486 | $400 | Implemented |
KU0202 # 07 Y:1986 | 07 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $365 | $0 | Implemented |
KU0202 # 08 Y:1986 | 08 | 1986 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $308 | $0 | Implemented |
KU0202 # 09 Y:1986 | 09 | 1986 | IMPROVE LUBRICATION PRACTICES | $284 | $300 | Implemented |
KU0202 # 10 Y:1986 | 10 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $210 | $50 | Implemented |
KU0202 # 11 Y:1986 | 11 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $213 | $0 | Not Implemented |
OK0207 # 01 Y:1986 | 01 | 1986 | KEEP LAMPS AND REFLECTORS CLEAN | $10,632 | $24,429 | Implemented |
OK0207 # 02 Y:1986 | 02 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $153 | $87 | Implemented |
OK0207 # 03 Y:1986 | 03 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $24 | $4 | Implemented |
OK0207 # 04 Y:1986 | 04 | 1986 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,124 | $8,200 | Implemented |
OK0207 # 05 Y:1986 | 05 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,466 | $1,200 | Implemented |
LT0061 # 01 Y:1986 | 01 | 1986 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,073 | $1,100 | Implemented |
LT0061 # 02 Y:1986 | 02 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $406 | $27 | Implemented |
LT0061 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,701 | $491 | Implemented |
OK0195 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,989 | $500 | Implemented |
OK0195 # 02 Y:1986 | 02 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $2,085 | $214 | Not Implemented |
OK0195 # 03 Y:1986 | 03 | 1986 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $2,520 | $3,000 | Implemented |
OK0195 # 04 Y:1986 | 04 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,902 | $0 | Implemented |
OK0195 # 05 Y:1986 | 05 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,289 | $1,200 | Implemented |
OK0195 # 06 Y:1986 | 06 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $582 | $0 | Implemented |
OK0195 # 07 Y:1986 | 07 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,030 | $1,200 | Implemented |
KU0200 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,229 | $14,500 | Implemented |
KU0200 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,130 | $1,000 | Implemented |
KU0200 # 03 Y:1986 | 03 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,694 | $0 | Implemented |