IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

15,260

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0051 # 07 Y:1982 07 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $125 $0 Not Implemented
KU0052 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $491 $1,329 Not Implemented
KU0052 # 02 Y:1982 02 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,003 $2,263 Not Implemented
KU0052 # 03 Y:1982 03 1982 UPGRADE OBSOLETE EQUIPMENT $6,450 $2,135 Not Implemented
KU0052 # 04 Y:1982 04 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $391 $360 Not Implemented
KU0052 # 05 Y:1982 05 1982 TURN OFF EQUIPMENT WHEN NOT IN USE $150 $0 Not Implemented
KU0053 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,126 $9,767 Implemented
KU0053 # 02 Y:1982 02 1982 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $24,341 $10,000 Implemented
KU0053 # 03 Y:1982 03 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,175 $360 Implemented
KU0053 # 04 Y:1982 04 1982 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $1,069 $250 Implemented
KU0053 # 05 Y:1982 05 1982 USE DEMAND CONTROLLER OR LOAD SHEDDER $9,630 $5,700 Not Implemented
KU0053 # 06 Y:1982 06 1982 INSULATE BARE EQUIPMENT $674 $90 Implemented
KU0053 # 07 Y:1982 07 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $256 $80 Implemented
KU0053 # 08 Y:1982 08 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,140 $1,320 Implemented
OK0038 # 01 Y:1982 01 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $217 $313 Not Implemented
OK0038 # 02 Y:1982 02 1982 USE RADIANT HEATER FOR SPOT HEATING $23,027 $29,970 Not Implemented
OK0038 # 03 Y:1982 03 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $259 $165 Not Implemented
OK0038 # 04 Y:1982 04 1982 INSTALL STORM WINDOWS AND DOORS $4,750 $17,358 Not Implemented
OK0050 # 01 Y:1982 01 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,801 $180 Not Implemented
OK0050 # 02 Y:1982 02 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $187 $330 Not Implemented
OK0050 # 03 Y:1982 03 1982 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $199 $17 Not Implemented
OK0050 # 04 Y:1982 04 1982 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $7,642 $80 Not Implemented
OK0050 # 05 Y:1982 05 1982 INSTALL TIMERS AND/OR THERMOSTATS $275 $790 Not Implemented
OK0050 # 06 Y:1982 06 1982 REDUCE FLUID FLOW RATES $595 $0 Not Implemented
OK0042 # 01 Y:1982 01 1982 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,978 $0 Not Implemented