Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

143

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0240 # 02 Y:1987 02 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,153 $0 Implemented
OK0240 # 04 Y:1987 04 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $576 $353 Implemented
OK0240 # 05 Y:1987 05 1987 INSULATE BARE EQUIPMENT $561 $240 Implemented
OK0240 # 08 Y:1987 08 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,004 $3,000 Implemented
OK0240 # 03 Y:1987 03 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,092 $0 Implemented
OK0240 # 06 Y:1987 06 1987 COVER OPEN TANKS $1,626 $269 Implemented
OK0240 # 01 Y:1987 01 1987 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,147 $5,000 Implemented
OK0240 # 07 Y:1987 07 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,858 $1,215 Implemented
MA0107 # 05 Y:1987 05 1987 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $266 $100 Not Implemented
MA0107 # 06 Y:1987 06 1987 INSULATE BARE EQUIPMENT $167 $98 Not Implemented
MA0107 # 02 Y:1987 02 1987 SHUT OFF PILOTS IN STANDBY EQUIPMENT $132 $0 Implemented
MA0107 # 04 Y:1987 04 1987 INSTALL TIMERS AND/OR THERMOSTATS $5,097 $1,800 Implemented
MA0107 # 03 Y:1987 03 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $7,636 $17,200 Implemented
MA0107 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,770 $664 Implemented
OK0239 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $140 $360 Not Implemented
OK0239 # 03 Y:1987 03 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $584 $0 Implemented
OK0239 # 01 Y:1987 01 1987 USE RADIANT HEATER FOR SPOT HEATING $2,300 $573 Not Implemented
MA0102 # 02 Y:1987 02 1987 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $263 $350 Implemented
MA0099 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $757 $136 Implemented
MA0099 # 01 Y:1987 01 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $183 $500 Implemented
MA0102 # 01 Y:1987 01 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $13,369 $400 Implemented
MA0099 # 03 Y:1987 03 1987 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $8,540 $30,000 Not Implemented
MA0102 # 05 Y:1987 05 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $342 $0 Not Implemented
MA0102 # 04 Y:1987 04 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,315 $168 Implemented
MA0099 # 04 Y:1987 04 1987 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $664 $800 Implemented