Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
236
matching recommendationsSIC | 351 | Engines And Turbines |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MO0199 # 04 Y:1997 | 04 | 1997 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $18,045 | $15,000 | Implemented |
MO0199 # 05 Y:1997 | 05 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $10,080 | $10,000 | Implemented |
MO0199 # 06 Y:1997 | 06 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,940 | $9,500 | Implemented |
MO0199 # 07 Y:1997 | 07 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $38,120 | $550 | Implemented |
MO0199 # 08 Y:1997 | 08 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,447 | $28,282 | Implemented |
AM0289 # 01 Y:1997 | 01 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $21,800 | $5,500 | Implemented |
AM0289 # 02 Y:1997 | 02 | 1997 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $1,830 | $1,050 | Implemented |
AM0289 # 03 Y:1997 | 03 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,330 | $0 | Implemented |
AM0289 # 04 Y:1997 | 04 | 1997 | BURN WASTE OIL FOR HEAT | $820 | $0 | Implemented |
AM0289 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $650 | $50 | Implemented |
AM0289 # 06 Y:1997 | 06 | 1997 | PAY UTILITY BILLS ON TIME | $600 | $0 | Implemented |
AM0289 # 07 Y:1997 | 07 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $440 | $0 | Implemented |
AM0289 # 08 Y:1997 | 08 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $230 | $100 | Implemented |
AM0289 # 09 Y:1997 | 09 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $170 | $0 | Implemented |
WI0287 # 06 Y:1997 | 06 | 1997 | TREAT AND REUSE RINSE WATERS | $1,041 | $1,475 | Implemented |
WI0287 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $439 | $736 | Implemented |
DS0069 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,691 | $4,761 | Implemented |
DS0069 # 02 Y:1996 | 02 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $969 | $0 | Implemented |
DS0069 # 04 Y:1996 | 04 | 1996 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $6,240 | $100 | Implemented |
DS0069 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,323 | $600 | Implemented |
KU0463 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,482 | $284 | Implemented |
KU0463 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $936 | $2,112 | Implemented |
KU0463 # 05 Y:1996 | 05 | 1996 | ADJUST BURNERS FOR EFFICIENT OPERATION | $633 | $1,000 | Implemented |
UL0161 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $21,995 | $21,995 | Implemented |
IA0096 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,198 | $350 | Implemented |