Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
24
matching recommendationsSIC | 3511 | Turbines And Turbine Generator Sets |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0390 # 03 Y:2006 | 03 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $87,992 | $39,000 | Not Implemented |
UF0390 # 14 Y:2006 | 14 | 2006 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $118,800 | $8,400 | Not Implemented |
UF0390 # 13 Y:2006 | 13 | 2006 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $979 | $4,996 | Not Implemented |
UF0390 # 12 Y:2006 | 12 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,655 | $1,610 | Not Implemented |
UF0390 # 11 Y:2006 | 11 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,152 | $36,122 | Not Implemented |
UF0390 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $437 | $347 | Not Implemented |
UF0390 # 09 Y:2006 | 09 | 2006 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $27,903 | $20,000 | Not Implemented |
UF0390 # 08 Y:2006 | 08 | 2006 | USE PHOTOCELL CONTROLS | $909 | $306 | Not Implemented |
UF0390 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,826 | $513 | Not Implemented |
UF0390 # 06 Y:2006 | 06 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,951 | $31,040 | Not Implemented |
UF0390 # 05 Y:2006 | 05 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,722 | $0 | Not Implemented |
UF0390 # 04 Y:2006 | 04 | 2006 | AIR CONDITION ONLY SPACE NECESSARY | $41,661 | $1,080 | Not Implemented |
UF0390 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,981 | $8,763 | Not Implemented |
UF0390 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $148,376 | $619,757 | Not Implemented |
UF0387 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $1,545 | $2,803 | Implemented |
UF0387 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $209 | $140 | Not Implemented |
UF0387 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,106 | $6,458 | Implemented |
UF0387 # 08 Y:2006 | 08 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,017 | $0 | Implemented |
UF0387 # 07 Y:2006 | 07 | 2006 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $21,479 | $0 | Implemented |
UF0387 # 06 Y:2006 | 06 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,577 | $370 | Implemented |
UF0387 # 05 Y:2006 | 05 | 2006 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $4,265 | $578 | Not Implemented |
UF0387 # 04 Y:2006 | 04 | 2006 | AIR CONDITION ONLY SPACE NECESSARY | $2,639 | $3,360 | Not Implemented |
UF0387 # 03 Y:2006 | 03 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,957 | $0 | Not Implemented |
UF0387 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,561 | $2,190 | Implemented |