Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 3523 | Farm Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0471 # 05 Y:2000 | 05 | 2000 | CONVERT TO ELECTROSTATIC POWDER COATING | $73,840 | $690,300 | Not Implemented |
CO0471 # 04 Y:2000 | 04 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,810 | $0 | Implemented |
CO0471 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $110 | $0 | Implemented |
CO0471 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $710 | $460 | Implemented |
CO0471 # 01 Y:2000 | 01 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,320 | $5,000 | Not Implemented |
CO0294 # 04 Y:1994 | 04 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $400 | $50 | Implemented |
CO0294 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,110 | $2,970 | Implemented |
CO0294 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,700 | $4,490 | Implemented |
CO0294 # 01 Y:1994 | 01 | 1994 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,230 | $15,000 | Not Implemented |
CO0180 # 04 Y:1990 | 04 | 1990 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,920 | $3,400 | Not Implemented |
CO0180 # 08 Y:1990 | 08 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $116 | $128 | Implemented |
CO0180 # 07 Y:1990 | 07 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $240 | $400 | Implemented |
CO0180 # 06 Y:1990 | 06 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $850 | $500 | Implemented |
CO0180 # 05 Y:1990 | 05 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,180 | $2,700 | Not Implemented |
CO0180 # 03 Y:1990 | 03 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $3,600 | $1,500 | Implemented |
CO0180 # 02 Y:1990 | 02 | 1990 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $6,850 | $6,700 | Not Implemented |
CO0180 # 01 Y:1990 | 01 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,040 | $12,000 | Not Implemented |
CO0044 # 01 Y:1985 | 01 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,425 | $5,000 | Not Implemented |
CO0044 # 10 Y:1985 | 10 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,073 | $1,930 | Not Implemented |
CO0044 # 09 Y:1985 | 09 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $6,495 | $122 | Implemented |
CO0044 # 08 Y:1985 | 08 | 1985 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $962 | $600 | Implemented |
CO0044 # 07 Y:1985 | 07 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $836 | $1,714 | Not Implemented |
CO0044 # 06 Y:1985 | 06 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,521 | $4,257 | Not Implemented |
CO0044 # 05 Y:1985 | 05 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $128 | $200 | Not Implemented |
CO0044 # 04 Y:1985 | 04 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $368 | $300 | Not Implemented |