Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
75
matching recommendationsSIC | 3545 | Machine Tool Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0061 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,417 | $1,162 | Implemented |
WV0061 # 09 Y:1995 | 09 | 1995 | USE SYNTHETIC LUBRICANT | $239 | $0 | Not Implemented |
UD0340 # 03 Y:1991 | 03 | 1991 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,840 | $5,000 | Implemented |
UD0340 # 02 Y:1991 | 02 | 1991 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,513 | $0 | Implemented |
UD0340 # 01 Y:1991 | 01 | 1991 | OPTIMIZE PLANT POWER FACTOR | $5,952 | $2,000 | Implemented |
UD0293 # 02 Y:1989 | 02 | 1989 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $776 | $0 | Not Implemented |
UD0293 # 01 Y:1989 | 01 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,133 | $0 | Not Implemented |
UD0293 # 03 Y:1989 | 03 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $725 | $1,000 | Not Implemented |
UD0293 # 05 Y:1989 | 05 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $287 | $0 | Not Implemented |
UD0293 # 04 Y:1989 | 04 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $498 | $39 | Not Implemented |
UD0279 # 01 Y:1989 | 01 | 1989 | MINIMIZE WATER USAGE | $1,243 | $300 | Not Implemented |
UD0279 # 03 Y:1989 | 03 | 1989 | TURN OFF EQUIPMENT WHEN NOT IN USE | $566 | $0 | Implemented |
UD0279 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,575 | $1,333 | Implemented |
UD0279 # 05 Y:1989 | 05 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,028 | $11,000 | Not Implemented |
UD0279 # 06 Y:1989 | 06 | 1989 | INSTALL STORM WINDOWS AND DOORS | $4,540 | $6,900 | Not Implemented |
UD0279 # 07 Y:1989 | 07 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,008 | $1,500 | Implemented |
UD0190 # 04 Y:1986 | 04 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,631 | $10,070 | Implemented |
UD0190 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,491 | $38,950 | Not Implemented |
UD0190 # 02 Y:1986 | 02 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,588 | $10,000 | Not Implemented |
UD0190 # 01 Y:1986 | 01 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,737 | $0 | Not Implemented |
UD0090 # 01 Y:1983 | 01 | 1983 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,380 | $8,000 | Not Implemented |
UD0090 # 05 Y:1983 | 05 | 1983 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $183 | $0 | Implemented |
UD0090 # 04 Y:1983 | 04 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,164 | $785 | Not Implemented |
UD0090 # 03 Y:1983 | 03 | 1983 | INSTALL STORM WINDOWS AND DOORS | $703 | $100 | Implemented |
UD0090 # 02 Y:1983 | 02 | 1983 | USE IMMERSION HEATING IN TANKS, MELTING POTS, ETC | $1,074 | $1,300 | Not Implemented |