Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
43
matching recommendationsSIC | 355 | Special Industry Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0286 # 02 Y:2020 | 02 | 2020 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,624 | $9,088 | Implemented |
MZ0286 # 04 Y:2020 | 04 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $22,970 | $2,000 | Implemented |
MZ0276 # 05 Y:2019 | 05 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $367 | $120 | Implemented |
MZ0276 # 03 Y:2019 | 03 | 2019 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,641 | $180 | Implemented |
MZ0276 # 02 Y:2019 | 02 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $249 | $1,040 | Implemented |
MZ0276 # 04 Y:2019 | 04 | 2019 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $44,070 | $184,040 | Implemented |
MZ0276 # 06 Y:2019 | 06 | 2019 | INSTALL OCCUPANCY SENSORS | $191 | $390 | Implemented |
MZ0276 # 01 Y:2019 | 01 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $155 | $60 | Implemented |
MZ0207 # 05 Y:2015 | 05 | 2015 | ELIMINATE/REDUCE AN OPERATION | $149 | $0 | Implemented |
MZ0207 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,482 | $3,430 | Implemented |
MZ0207 # 01 Y:2015 | 01 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,485 | $27,300 | Implemented |
MZ0207 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,538 | $880 | Implemented |
MZ0002 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,930 | $40,700 | Implemented |
IA0347 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,623 | $920 | Implemented |
IA0347 # 03 Y:2004 | 03 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,243 | $1,090 | Implemented |
IA0347 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,608 | $2,591 | Implemented |
IA0347 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $1,911 | $1,820 | Implemented |
IA0347 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $929 | $457 | Implemented |
IA0347 # 07 Y:2004 | 07 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,967 | $148 | Implemented |
IA0347 # 09 Y:2004 | 09 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $244 | $0 | Implemented |
MO0135 # 08 Y:1994 | 08 | 1994 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $77 | $150 | Implemented |
MO0135 # 07 Y:1994 | 07 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $523 | $240 | Implemented |
MO0135 # 06 Y:1994 | 06 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,447 | $4,559 | Implemented |
MO0135 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,831 | $18,231 | Implemented |
MO0135 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,507 | $612 | Implemented |