Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,577
matching recommendationsSIC | 355 | Special Industry Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0096 # 05 Y:1997 | 05 | 1997 | MOVE PRODUCT USING MECHANICAL MEANS | $640 | $4,500 | Implemented |
IA0169 # 01 Y:1997 | 01 | 1997 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $15,243 | $4,200 | Not Implemented |
IA0169 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,457 | $25,564 | Implemented |
IA0169 # 03 Y:1997 | 03 | 1997 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,357 | $4,900 | Implemented |
IA0169 # 04 Y:1997 | 04 | 1997 | REDUCE VENTILATION AIR | $2,334 | $40 | Implemented |
IA0169 # 05 Y:1997 | 05 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,649 | $7,400 | Not Implemented |
IA0169 # 06 Y:1997 | 06 | 1997 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,535 | $4,500 | Not Implemented |
IA0169 # 07 Y:1997 | 07 | 1997 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $4,866 | $2,300 | Not Implemented |
IA0169 # 08 Y:1997 | 08 | 1997 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $1,124 | $0 | Not Implemented |
IA0169 # 09 Y:1997 | 09 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $665 | $110 | Implemented |
IA0169 # 10 Y:1997 | 10 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $229 | $14 | Not Implemented |
IA0169 # 11 Y:1997 | 11 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $103 | $205 | Implemented |
MA0398 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,098 | $34,200 | Not Implemented |
MA0398 # 02 Y:1997 | 02 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $2,759 | $10,560 | Not Implemented |
MA0398 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,450 | $384 | Implemented |
MA0398 # 04 Y:1997 | 04 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,067 | $0 | Implemented |
MA0398 # 05 Y:1997 | 05 | 1997 | PAY BILLS ON TIME TO AVOID LATE FEES | $346 | $0 | Implemented |
NC0117 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $271 | $499 | Implemented |
NC0117 # 02 Y:1997 | 02 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $100 | $111 | Implemented |
NC0117 # 03 Y:1997 | 03 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $791 | $140 | Implemented |
NC0117 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $22 | $48 | Implemented |
NC0117 # 05 Y:1997 | 05 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $187 | $149 | Implemented |
NC0117 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $886 | $982 | Implemented |
NC0117 # 07 Y:1997 | 07 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,289 | $600 | Implemented |
NC0117 # 08 Y:1997 | 08 | 1997 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $8,850 | $1,000 | Implemented |