Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 1997 |
Principal Product | High Pressure Water Jetting Systems |
NAICS | n/a |
SIC | 3559 - Special Industry Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 145 |
Plant Area (Sq.Ft.) | 40,200 |
Annual Production | 216,000 Units |
Production Hrs. Annual | 6,552 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $144,663 | 1,464,830 | kWh | $0.10 |
Electricity Fees | $3,146 | - | $ | - |
Natural Gas | $28,869 | 7,141 | MMBtu | $4.04 |
TOTAL ENERGY COSTS | $278,028 | |||
RECOMMENDED SAVINGS* | $40,264 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $34,786 |
#|Description |
Savings Cost |
Status | Electricity Usage | Other Liquid (haz) | By-product Production | Electricity Usage | Other Liquid (haz) | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,791 Cost: $2,165 |
$1,791 | 17,878 | - | - | - | - |
$1,791 17,878 kWh |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,478 Cost: $9,846 |
$5,478 | 54,807 | - | - | - | - |
$5,478 54,807 kWh |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,896 Cost: $1,000 |
$1,896 | 19,050 | - | - | - | - |
$1,896 19,050 kWh |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $30,459 Cost: $1,000 |
- | - | $30,459 | 147 | - | - |
- - kWh |
$30,459 147 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $640 Cost: $4,500 |
- | - | - | - | $640 | - |
- - kWh |
- - gal |
$640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $40,264 Cost: $18,511 |
$9,165 | 91,735 | $30,459 | 147 | $640 | - | $9,165 91,735 kWh |
$30,459 147 gal |
$640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $34,786 Cost: $8,665 |
$3,687 | 36,928 | $30,459 | 147 | $640 | - | $3,687 36,928 kWh |
$30,459 147 gal |
$640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Other Liquid (haz) | By-product Production | Electricity Usage | Other Liquid (haz) | By-product Production |