Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,577
matching recommendationsSIC | 355 | Special Industry Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0021 # 04 Y:1995 | 04 | 1995 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $52 | $20 | Not Implemented |
BD0021 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,119 | $1,064 | Not Implemented |
BD0021 # 06 Y:1995 | 06 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,041 | $552 | Implemented |
BD0021 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $186 | $285 | Not Implemented |
MO0135 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,507 | $612 | Implemented |
MO0135 # 02 Y:1994 | 02 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $387 | $344 | Not Implemented |
MO0135 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $331 | $410 | Not Implemented |
MO0135 # 04 Y:1994 | 04 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $211 | $50 | Not Implemented |
MO0135 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,831 | $18,231 | Implemented |
MO0135 # 06 Y:1994 | 06 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,447 | $4,559 | Implemented |
MO0135 # 07 Y:1994 | 07 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $523 | $240 | Implemented |
MO0135 # 08 Y:1994 | 08 | 1994 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $77 | $150 | Implemented |
NC0041 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,492 | $300 | Implemented |
NC0041 # 02 Y:1994 | 02 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,252 | $15,600 | Implemented |
NC0041 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,145 | $926 | Not Implemented |
NC0041 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,005 | $14,685 | Implemented |
NC0041 # 05 Y:1994 | 05 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,282 | $500 | Not Implemented |
NC0041 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $190 | $2,000 | Implemented |
NC0041 # 07 Y:1994 | 07 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $725 | $1,060 | Implemented |
OR0217 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,943 | $5,465 | Implemented |
OR0217 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,072 | $15,891 | Implemented |
OR0217 # 03 Y:1994 | 03 | 1994 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $1,880 | $3,200 | Implemented |
OR0217 # 04 Y:1994 | 04 | 1994 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $8,519 | $20,000 | Not Implemented |
OR0217 # 05 Y:1994 | 05 | 1994 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,470 | $0 | Implemented |
MO0126 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,096 | $12,303 | Implemented |