Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,577
matching recommendationsSIC | 355 | Special Industry Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0040 # 12 Y:1985 | 12 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,066 | $1,000 | Implemented |
TS0009 # 01 Y:1985 | 01 | 1985 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $14,940 | $8,000 | Not Implemented |
TS0009 # 02 Y:1985 | 02 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $111 | $10 | Not Implemented |
TS0009 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,498 | $0 | Not Implemented |
TS0009 # 04 Y:1985 | 04 | 1985 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,460 | $1,200 | Not Implemented |
TS0009 # 05 Y:1985 | 05 | 1985 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $400 | $0 | Not Implemented |
TS0009 # 06 Y:1985 | 06 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $581 | $600 | Not Implemented |
UD0148 # 01 Y:1985 | 01 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,500 | $300 | Implemented |
UD0148 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,111 | $2,395 | Implemented |
UD0148 # 03 Y:1985 | 03 | 1985 | INSULATE BARE EQUIPMENT | $994 | $1,560 | Not Implemented |
ST0009 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,275 | $212 | Not Implemented |
ST0009 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $201 | $537 | Implemented |
ST0009 # 03 Y:1984 | 03 | 1984 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $50 | $0 | Implemented |
ST0009 # 04 Y:1984 | 04 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $136 | $0 | Implemented |
ST0009 # 05 Y:1984 | 05 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $40 | $50 | Implemented |
ST0009 # 06 Y:1984 | 06 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $32 | $28 | Not Implemented |
ST0009 # 07 Y:1984 | 07 | 1984 | INSTALL AUTOMATIC STACK DAMPER | $251 | $60 | Not Implemented |
ST0009 # 08 Y:1984 | 08 | 1984 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,149 | $0 | Implemented |
ST0009 # 09 Y:1984 | 09 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $679 | $130 | Not Implemented |
ST0009 # 10 Y:1984 | 10 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $370 | $750 | Not Implemented |
LT0010 # 01 Y:1984 | 01 | 1984 | INSULATE BARE EQUIPMENT | $157 | $200 | Implemented |
LT0010 # 02 Y:1984 | 02 | 1984 | COVER OPEN TANKS | $174 | $48 | Implemented |
LT0010 # 03 Y:1984 | 03 | 1984 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $605 | $74 | Not Implemented |
LT0010 # 04 Y:1984 | 04 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $2,412 | $0 | Implemented |
LT0010 # 05 Y:1984 | 05 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $522 | $400 | Implemented |