Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,477
matching recommendationsSIC | 356 | General Industrial Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0125 # 01 Y:1984 | 01 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,583 | $11,079 | Implemented |
UD0125 # 02 Y:1984 | 02 | 1984 | COVER OPEN TANKS | $1,611 | $1,080 | Implemented |
UD0125 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,474 | $5,156 | Implemented |
OK0140 # 05 Y:1984 | 05 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $698 | $126 | Implemented |
UD0124 # 01 Y:1984 | 01 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,949 | $30,000 | Implemented |
UD0124 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,158 | $1,674 | Implemented |
UD0124 # 03 Y:1984 | 03 | 1984 | INSULATE BARE EQUIPMENT | $1,892 | $1,000 | Implemented |
GT0197 # 02 Y:1983 | 02 | 1983 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $18,971 | $10,500 | Implemented |
GT0197 # 04 Y:1983 | 04 | 1983 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $9,026 | $0 | Implemented |
GT0190 # 03 Y:1983 | 03 | 1983 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $9,468 | $9,000 | Implemented |
OK0097 # 02 Y:1983 | 02 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $146 | $99 | Implemented |
OK0074 # 01 Y:1983 | 01 | 1983 | REDUCE VENTILATION AIR | $1,596 | $69 | Implemented |
OK0074 # 03 Y:1983 | 03 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $6,118 | $439 | Implemented |
OK0074 # 04 Y:1983 | 04 | 1983 | REDUCE VENTILATION AIR | $2,218 | $1,863 | Implemented |
KU0071 # 03 Y:1983 | 03 | 1983 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,367 | $580 | Implemented |
KU0071 # 05 Y:1983 | 05 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,450 | $30 | Implemented |
KU0071 # 07 Y:1983 | 07 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $798 | $250 | Implemented |
KU0071 # 10 Y:1983 | 10 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $124 | $87 | Implemented |
UD0063 # 03 Y:1982 | 03 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,592 | $61 | Implemented |
UD0063 # 04 Y:1982 | 04 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $29,194 | $42,215 | Implemented |
OK0052 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $1,693 | $485 | Implemented |
OK0052 # 04 Y:1982 | 04 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,144 | $83 | Implemented |
OK0052 # 06 Y:1982 | 06 | 1982 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,202 | $64 | Implemented |
KU0062 # 04 Y:1982 | 04 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $370 | $272 | Implemented |
KU0044 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $59,143 | $92,496 | Implemented |