Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,477

matching recommendations
Reset
SIC 356 General Industrial Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0125 # 01 Y:1984 01 1984 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $11,583 $11,079 Implemented
UD0125 # 02 Y:1984 02 1984 COVER OPEN TANKS $1,611 $1,080 Implemented
UD0125 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,474 $5,156 Implemented
OK0140 # 05 Y:1984 05 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $698 $126 Implemented
UD0124 # 01 Y:1984 01 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,949 $30,000 Implemented
UD0124 # 02 Y:1984 02 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,158 $1,674 Implemented
UD0124 # 03 Y:1984 03 1984 INSULATE BARE EQUIPMENT $1,892 $1,000 Implemented
GT0197 # 02 Y:1983 02 1983 USE DEMAND CONTROLLER OR LOAD SHEDDER $18,971 $10,500 Implemented
GT0197 # 04 Y:1983 04 1983 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $9,026 $0 Implemented
GT0190 # 03 Y:1983 03 1983 USE DEMAND CONTROLLER OR LOAD SHEDDER $9,468 $9,000 Implemented
OK0097 # 02 Y:1983 02 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $146 $99 Implemented
OK0074 # 01 Y:1983 01 1983 REDUCE VENTILATION AIR $1,596 $69 Implemented
OK0074 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $6,118 $439 Implemented
OK0074 # 04 Y:1983 04 1983 REDUCE VENTILATION AIR $2,218 $1,863 Implemented
KU0071 # 03 Y:1983 03 1983 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $3,367 $580 Implemented
KU0071 # 05 Y:1983 05 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,450 $30 Implemented
KU0071 # 07 Y:1983 07 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $798 $250 Implemented
KU0071 # 10 Y:1983 10 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $124 $87 Implemented
UD0063 # 03 Y:1982 03 1982 RECOVER WASTE HEAT FROM EQUIPMENT $1,592 $61 Implemented
UD0063 # 04 Y:1982 04 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $29,194 $42,215 Implemented
OK0052 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $1,693 $485 Implemented
OK0052 # 04 Y:1982 04 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,144 $83 Implemented
OK0052 # 06 Y:1982 06 1982 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $2,202 $64 Implemented
KU0062 # 04 Y:1982 04 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $370 $272 Implemented
KU0044 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $59,143 $92,496 Implemented