Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsSIC | 356 | General Industrial Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0194 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,836 | $7,316 | Not Implemented |
UF0194 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,194 | $951 | Not Implemented |
UF0194 # 11 Y:1998 | 11 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,635 | $3,215 | Implemented |
UF0194 # 10 Y:1998 | 10 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $2,468 | $7,000 | Not Implemented |
UF0194 # 09 Y:1998 | 09 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $9,559 | $9,000 | Not Implemented |
UF0194 # 08 Y:1998 | 08 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $781 | $850 | Implemented |
UF0194 # 07 Y:1998 | 07 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $144 | $400 | Implemented |
UF0164 # 07 Y:1996 | 07 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $3,240 | $0 | Implemented |
UF0164 # 06 Y:1996 | 06 | 1996 | AIR CONDITION ONLY SPACE NECESSARY | $8,857 | $880 | Not Implemented |
UF0164 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,142 | $600 | Implemented |
UF0164 # 04 Y:1996 | 04 | 1996 | MOVE BOILER TO MORE EFFICIENT LOCATION | $10,185 | $0 | Implemented |
UF0164 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,265 | $3,303 | Implemented |
UF0164 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,368 | $16,471 | Not Implemented |
UF0164 # 01 Y:1996 | 01 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $97,999 | $5,544 | Not Implemented |
UF0095 # 06 Y:1994 | 06 | 1994 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $49,423 | $76,330 | Not Implemented |
UF0095 # 07 Y:1994 | 07 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $554 | $794 | Implemented |
UF0095 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,948 | $39,507 | Implemented |
UF0095 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,388 | $1,750 | Implemented |
UF0095 # 03 Y:1994 | 03 | 1994 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $16,867 | $24,660 | Implemented |
UF0095 # 04 Y:1994 | 04 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $6,763 | $22,550 | Not Implemented |
UF0095 # 05 Y:1994 | 05 | 1994 | REPLACE ELECTRIC REHEAT WITH HEAT PIPES | $11,259 | $38,450 | Not Implemented |
UF0022 # 05 Y:1992 | 05 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $57 | $440 | Not Implemented |
UF0022 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $214 | $2,840 | Not Implemented |
UF0022 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24 | $1,949 | Not Implemented |
UF0022 # 02 Y:1992 | 02 | 1992 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,035 | $5,760 | Not Implemented |