IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

78

matching recommendations
Reset
SIC 356 General Industrial Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0144 # 08 Y:1984 08 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $160 $0 Implemented
KU0144 # 07 Y:1984 07 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,279 $39 Implemented
KU0144 # 05 Y:1984 05 1984 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $1,578 $0 Implemented
KU0144 # 04 Y:1984 04 1984 INSTALL AUTOMATIC STACK DAMPER $2,157 $1,900 Not Implemented
KU0144 # 03 Y:1984 03 1984 IMPROVE LUBRICATION PRACTICES $1,597 $0 Implemented
KU0144 # 02 Y:1984 02 1984 USE DEMAND CONTROLLER OR LOAD SHEDDER $3,395 $4,000 Implemented
KU0144 # 01 Y:1984 01 1984 REDUCE VENTILATION AIR $11,229 $0 Not Implemented
KU0144 # 10 Y:1984 10 1984 RECOVER WASTE HEAT FROM EQUIPMENT $753 $400 Implemented
KU0071 # 05 Y:1983 05 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,450 $30 Implemented
KU0071 # 01 Y:1983 01 1983 AIR CONDITION ONLY SPACE NECESSARY $10,942 $5,000 Not Implemented
KU0071 # 02 Y:1983 02 1983 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $3,528 $15,000 Not Implemented
KU0071 # 03 Y:1983 03 1983 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $3,367 $580 Implemented
KU0071 # 04 Y:1983 04 1983 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,383 $862 Not Implemented
KU0071 # 06 Y:1983 06 1983 INSTALL AUTOMATIC STACK DAMPER $1,202 $720 Not Implemented
KU0071 # 07 Y:1983 07 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $798 $250 Implemented
KU0071 # 08 Y:1983 08 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $593 $200 Not Implemented
KU0071 # 09 Y:1983 09 1983 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $330 $0 Not Implemented
KU0071 # 10 Y:1983 10 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $124 $87 Implemented
KU0062 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,547 $2,445 Not Implemented
KU0062 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $1,446 $800 Not Implemented
KU0062 # 03 Y:1982 03 1982 INSTALL AUTOMATIC STACK DAMPER $485 $576 Not Implemented
KU0062 # 04 Y:1982 04 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $370 $272 Implemented
KU0044 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $59,143 $92,496 Implemented
KU0044 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $6,923 $4,000 Not Implemented
KU0044 # 03 Y:1982 03 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,715 $500 Implemented