Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
617
matching recommendationsSIC | 3561 | Pumps And Pumping Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0346 # 01 Y:1988 | 01 | 1988 | USE RADIANT HEATER FOR SPOT HEATING | $1,950 | $3,600 | Not Implemented |
GT0346 # 02 Y:1988 | 02 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $170 | $259 | Implemented |
GT0346 # 03 Y:1988 | 03 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $450 | $0 | Not Implemented |
GT0346 # 04 Y:1988 | 04 | 1988 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $558 | $20 | Not Implemented |
GT0346 # 05 Y:1988 | 05 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $660 | $350 | Not Implemented |
GT0346 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $105 | $202 | Not Implemented |
GT0346 # 07 Y:1988 | 07 | 1988 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,760 | $2,640 | Not Implemented |
GT0346 # 08 Y:1988 | 08 | 1988 | INSULATE BARE EQUIPMENT | $160 | $30 | Not Implemented |
WI0034 # 01 Y:1988 | 01 | 1988 | IMPROVE LUBRICATION PRACTICES | $9,202 | $0 | Implemented |
WI0034 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,718 | $0 | Implemented |
WI0034 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,480 | $6,401 | Implemented |
WI0034 # 04 Y:1988 | 04 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $434 | $0 | Implemented |
WI0034 # 05 Y:1988 | 05 | 1988 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,338 | $20,000 | Not Implemented |
OK0195 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,989 | $500 | Implemented |
OK0195 # 02 Y:1986 | 02 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $2,085 | $214 | Not Implemented |
OK0195 # 03 Y:1986 | 03 | 1986 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $2,520 | $3,000 | Implemented |
OK0195 # 04 Y:1986 | 04 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,902 | $0 | Implemented |
OK0195 # 05 Y:1986 | 05 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,289 | $1,200 | Implemented |
OK0195 # 06 Y:1986 | 06 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $582 | $0 | Implemented |
OK0195 # 07 Y:1986 | 07 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,030 | $1,200 | Implemented |
CO0046 # 01 Y:1985 | 01 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,907 | $6,000 | Not Implemented |
CO0046 # 02 Y:1985 | 02 | 1985 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $10,101 | $4,825 | Not Implemented |
CO0046 # 03 Y:1985 | 03 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,126 | $29,000 | Not Implemented |
CO0046 # 04 Y:1985 | 04 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,962 | $2,990 | Not Implemented |
CO0046 # 05 Y:1985 | 05 | 1985 | INSTALL STORM WINDOWS AND DOORS | $669 | $650 | Not Implemented |