matching recommendationsSIC | 3566 | Speed Changers, Drives, And Gears |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0518 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,334 | $1,000 | Implemented |
TN0518 # 02 Y:1994 | 02 | 1994 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $10,859 | $13,300 | Not Implemented |
TN0518 # 03 Y:1994 | 03 | 1994 | REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH | $11,508 | $5,200 | Not Implemented |
TN0518 # 04 Y:1994 | 04 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $7,597 | $5,400 | Not Implemented |
TN0518 # 05 Y:1994 | 05 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,005 | $360 | Not Implemented |
TN0518 # 06 Y:1994 | 06 | 1994 | INSULATE BARE EQUIPMENT | $6,176 | $605 | Not Implemented |
TN0518 # 07 Y:1994 | 07 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,013 | $200 | Implemented |
TN0518 # 08 Y:1994 | 08 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $98 | $108 | Implemented |
WI0112 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,926 | $153 | Implemented |
WI0112 # 02 Y:1991 | 02 | 1991 | IMPROVE LUBRICATION PRACTICES | $712 | $0 | Implemented |
WI0112 # 03 Y:1991 | 03 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $692 | $640 | Implemented |
WI0112 # 04 Y:1991 | 04 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $604 | $0 | Implemented |
WI0112 # 05 Y:1991 | 05 | 1991 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $586 | $0 | Implemented |
WI0112 # 06 Y:1991 | 06 | 1991 | INSTALL STORM WINDOWS AND DOORS | $321 | $812 | Implemented |
WI0112 # 07 Y:1991 | 07 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $263 | $200 | Implemented |
WI0112 # 08 Y:1991 | 08 | 1991 | INSTALL SET-BACK TIMERS | $180 | $200 | Implemented |
WI0112 # 09 Y:1991 | 09 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $132 | $300 | Implemented |
WI0112 # 10 Y:1991 | 10 | 1991 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $73 | $0 | Implemented |
UD0314 # 01 Y:1990 | 01 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,571 | $25,000 | Implemented |
UD0314 # 02 Y:1990 | 02 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,218 | $14,000 | Implemented |
UD0314 # 03 Y:1990 | 03 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,489 | $8,000 | Implemented |
UD0314 # 04 Y:1990 | 04 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,341 | $6,000 | Not Implemented |
UD0314 # 05 Y:1990 | 05 | 1990 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $7,638 | $0 | Not Implemented |
UD0314 # 06 Y:1990 | 06 | 1990 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $16,450 | $500 | Not Implemented |
UD0314 # 07 Y:1990 | 07 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,223 | $33,000 | Implemented |