Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
442
matching recommendationsSIC | 357 | Computer And Office Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AT0056 # 04 Y:1986 | 04 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $604 | $100 | Not Implemented |
AT0056 # 05 Y:1986 | 05 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,087 | $2,000 | Not Implemented |
AT0056 # 06 Y:1986 | 06 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $1,033 | $0 | Implemented |
AT0056 # 07 Y:1986 | 07 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $738 | $0 | Implemented |
AT0056 # 08 Y:1986 | 08 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $6,965 | $1,000 | Not Implemented |
AT0056 # 09 Y:1986 | 09 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $15,428 | $10,000 | Not Implemented |
OK0207 # 01 Y:1986 | 01 | 1986 | KEEP LAMPS AND REFLECTORS CLEAN | $10,632 | $24,429 | Implemented |
OK0207 # 02 Y:1986 | 02 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $153 | $87 | Implemented |
OK0207 # 03 Y:1986 | 03 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $24 | $4 | Implemented |
OK0207 # 04 Y:1986 | 04 | 1986 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,124 | $8,200 | Implemented |
OK0207 # 05 Y:1986 | 05 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,466 | $1,200 | Implemented |
CO0045 # 01 Y:1985 | 01 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,273 | $1,500 | Not Implemented |
CO0045 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,736 | $300 | Implemented |
CO0045 # 03 Y:1985 | 03 | 1985 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,875 | $200 | Not Implemented |
CO0045 # 04 Y:1985 | 04 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $559 | $400 | Not Implemented |
CO0045 # 05 Y:1985 | 05 | 1985 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $440 | $300 | Implemented |
CO0045 # 06 Y:1985 | 06 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,215 | $6,411 | Implemented |