Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
67
matching recommendationsSIC | 3571 | Electronic Computers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0122 # 04 Y:2007 | 04 | 2007 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $19,128 | $5,500 | Implemented |
LM0122 # 05 Y:2007 | 05 | 2007 | MODIFY WORKLOAD | $9,311 | $4,850 | Implemented |
LM0122 # 02 Y:2007 | 02 | 2007 | ISOLATE HOT OR COLD EQUIPMENT | $814 | $2,000 | Not Implemented |
LM0122 # 03 Y:2007 | 03 | 2007 | INSTALL OCCUPANCY SENSORS | $1,465 | $3,975 | Not Implemented |
LM0122 # 01 Y:2007 | 01 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $42,830 | $89,250 | Not Implemented |
UF0376 # 05 Y:2006 | 05 | 2006 | AIR CONDITION ONLY SPACE NECESSARY | $1,014 | $3,200 | Not Implemented |
UF0376 # 08 Y:2006 | 08 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $148 | $0 | Not Implemented |
UF0376 # 07 Y:2006 | 07 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $369 | $0 | Not Implemented |
UF0376 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,968 | $27,399 | Not Implemented |
UF0376 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,222 | $2,053 | Not Implemented |
UF0376 # 03 Y:2006 | 03 | 2006 | ADD AREA LIGHTING SWITCHES | $878 | $2,646 | Not Implemented |
UF0376 # 06 Y:2006 | 06 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $150 | $1,480 | Not Implemented |
UF0376 # 04 Y:2006 | 04 | 2006 | INSTALL BACK-UP EQUIPMENT | $1,632,456 | $5,315 | Not Implemented |
UM0145 # 07 Y:1999 | 07 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $16,869 | $14,495 | Implemented |
UM0145 # 08 Y:1999 | 08 | 1999 | INSTALL MAGAZINES FOR TEMPORARY STORAGE | $32,500 | $2,000 | Not Implemented |
UM0145 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,978 | $11,600 | Not Implemented |
UM0145 # 03 Y:1999 | 03 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,970 | $40,000 | Not Implemented |
UM0145 # 06 Y:1999 | 06 | 1999 | USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS | $24,222 | $60,000 | Implemented |
UM0145 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,720 | $300 | Implemented |
UM0145 # 05 Y:1999 | 05 | 1999 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $50,143 | $85,000 | Not Implemented |
UM0145 # 02 Y:1999 | 02 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $2,157 | $4,500 | Not Implemented |
NV0114 # 03 Y:1998 | 03 | 1998 | INSTALL SKYLIGHTS | $1,349 | $3,308 | Not Implemented |
NV0114 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $332 | $275 | Not Implemented |
NV0114 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,835 | $13,808 | Not Implemented |
DS0071 # 03 Y:1996 | 03 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $12,255 | $0 | Implemented |