Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

134

matching recommendations
Reset
SIC 3577 Computer Peripheral Equipment, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0169 # 01 Y:1997 01 1997 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $20,154 $3,300 Implemented
SD0169 # 02 Y:1997 02 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,714 $11,700 Implemented
SD0169 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,459 $0 Implemented
SD0169 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $941 $469 Implemented
SD0169 # 05 Y:1997 05 1997 INSTALL SPECTRAL REFLECTORS / DELAMP $1,809 $4,110 Implemented
SD0169 # 06 Y:1997 06 1997 INSTALL OCCUPANCY SENSORS $1,082 $1,845 Implemented
SD0169 # 07 Y:1997 07 1997 CONVERT TO LESS TOXIC HYDROCARBON CLEANERS $1,894 $0 Not Implemented
SD0169 # 08 Y:1997 08 1997 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS $11,496 $3,480 Implemented
SD0169 # 09 Y:1997 09 1997 CHANGE PRODUCT SPECS $39,867 $0 Not Implemented
SD0158 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,616 $2,210 Implemented
SD0158 # 02 Y:1996 02 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,410 $40 Not Implemented
SD0158 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $371 $756 Implemented
SD0158 # 04 Y:1996 04 1996 INSTALL SPECTRAL REFLECTORS / DELAMP $3,949 $6,275 Implemented
SD0158 # 05 Y:1996 05 1996 RECYCLE CLEANING SOLVENT AND REUSE $7,908 $7,200 Implemented
ME0147 # 01 Y:1995 01 1995 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $44,899 $0 Not Implemented
ME0147 # 02 Y:1995 02 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $26,440 $6,100 Not Implemented
ME0147 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,133 $3,264 Implemented
ME0147 # 04 Y:1995 04 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,961 $4,160 Not Implemented
ME0147 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $1,858 $2,365 Not Implemented
ME0147 # 06 Y:1995 06 1995 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $1,311 $370 Not Implemented
ME0147 # 07 Y:1995 07 1995 INSTALL OCCUPANCY SENSORS $1,260 $300 Not Implemented
ME0147 # 08 Y:1995 08 1995 PAY UTILITY BILLS ON TIME $1,077 $0 Implemented
ME0147 # 09 Y:1995 09 1995 MINIMIZE WATER USAGE $4,092 $60,000 Not Implemented
ME0147 # 10 Y:1995 10 1995 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $6,122 $650 Implemented
ME0147 # 11 Y:1995 11 1995 MINIMIZE WATER USAGE $727 $440 Implemented