Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
91
matching recommendationsSIC | 358 | Refrigeration And Service Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0381 # 02 Y:2011 | 02 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $31,659 | $34,108 | Not Implemented |
MS0381 # 03 Y:2011 | 03 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $264 | $317 | Not Implemented |
MS0373 # 02 Y:2011 | 02 | 2011 | BURN A LESS EXPENSIVE GRADE OF FUEL | $32,874 | $100,490 | Not Implemented |
MS0373 # 01 Y:2011 | 01 | 2011 | BURN A LESS EXPENSIVE GRADE OF FUEL | $26,816 | $43,705 | Not Implemented |
MS0361 # 04 Y:2010 | 04 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $851 | $604 | Not Implemented |
MS0361 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,596 | $322 | Implemented |
MS0361 # 02 Y:2010 | 02 | 2010 | BURN A LESS EXPENSIVE GRADE OF FUEL | $28,668 | $57,500 | Not Implemented |
MS0361 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $86,285 | $59,157 | Implemented |
MS0349 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $3,399 | $671 | Not Implemented |
MS0349 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,685 | $389 | Implemented |
MS0349 # 02 Y:2010 | 02 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,920 | $140 | Not Implemented |
MS0349 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,903 | $31,050 | Implemented |
MS0323 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,492 | $8,771 | Implemented |
MS0323 # 05 Y:2008 | 05 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $257 | $450 | Implemented |
MS0323 # 03 Y:2008 | 03 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,739 | $3,030 | Implemented |
MS0323 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,013 | $266 | Implemented |
MS0323 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,680 | $26,178 | Implemented |
MS0312 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $551 | $4,911 | Not Implemented |
MS0312 # 03 Y:2007 | 03 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,372 | $135 | Not Implemented |
MS0312 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,170 | $1,559 | Not Implemented |
MS0312 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,487 | $38,702 | Not Implemented |
MS0221 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $460 | $585 | Not Implemented |
MS0221 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,834 | $782 | Implemented |
MS0221 # 02 Y:2003 | 02 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,072 | $12,006 | Not Implemented |
MS0221 # 01 Y:2003 | 01 | 2003 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $202,950 | $8,100 | Implemented |