Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

35

matching recommendations
Reset
SIC 3585 Refrigeration And Heating Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0328 # 07 Y:2012 07 2012 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $13,560 $54,280 Implemented
SU0328 # 06 Y:2012 06 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $309 $758 Not Implemented
SU0328 # 05 Y:2012 05 2012 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,923 $2,382 Implemented
SU0328 # 04 Y:2012 04 2012 ELIMINATE/REDUCE AN OPERATION $4,336 $4,060 Not Implemented
SU0328 # 03 Y:2012 03 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $678 $611 Implemented
SU0328 # 02 Y:2012 02 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,399 $1,890 Not Implemented
SU0328 # 01 Y:2012 01 2012 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $164 $0 Implemented
WV0452 # 06 Y:2012 06 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,772 $54,225 Not Implemented
WV0452 # 03 Y:2012 03 2012 REPAIR OR REPLACE STEAM TRAPS $21,578 $4,825 Implemented
WV0452 # 04 Y:2012 04 2012 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $16,198 $8,840 Not Implemented
WV0452 # 05 Y:2012 05 2012 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $14,172 $1,000 Implemented
WV0452 # 16 Y:2012 16 2012 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $277 $85 Implemented
WV0452 # 07 Y:2012 07 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,507 $2,500 Implemented
WV0452 # 08 Y:2012 08 2012 DEVELOP A REPAIR/REPLACE POLICY $6,936 $1,656 Implemented
WV0452 # 09 Y:2012 09 2012 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,587 $1,000 Implemented
WV0452 # 10 Y:2012 10 2012 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,515 $2,117 Not Implemented
WV0452 # 11 Y:2012 11 2012 INSTALL / REPAIR INSULATION ON STEAM LINES $3,487 $10,561 Not Implemented
WV0452 # 12 Y:2012 12 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,146 $618 Implemented
WV0452 # 13 Y:2012 13 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,098 $1,105 Implemented
WV0452 # 14 Y:2012 14 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $873 $4,350 Not Implemented
WV0452 # 15 Y:2012 15 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $431 $1,505 Not Implemented
WV0452 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $40,485 $98,452 Not Implemented
WV0452 # 01 Y:2012 01 2012 USE RADIANT HEATER FOR SPOT HEATING $50,506 $36,000 Not Implemented
MZ0088 # 05 Y:2012 05 2012 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $698 $1,200 Not Implemented
MZ0088 # 04 Y:2012 04 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,252 $2,400 Not Implemented