Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
427
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0026 # 03 Y:2002 | 03 | 2002 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,230 | $0 | Not Implemented |
TA0026 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $980 | $400 | Implemented |
TA0026 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $875 | $346 | Implemented |
TA0026 # 06 Y:2002 | 06 | 2002 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $500 | $0 | Implemented |
TA0026 # 07 Y:2002 | 07 | 2002 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $214 | $0 | Implemented |
TA0021 # 01 Y:2002 | 01 | 2002 | INSTALL / REPAIR INSULATION ON STEAM LINES | $11,450 | $5,883 | Implemented |
TA0021 # 02 Y:2002 | 02 | 2002 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,736 | $19,010 | Not Implemented |
TA0021 # 03 Y:2002 | 03 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $6,110 | $190 | Implemented |
TA0021 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $864 | $504 | Implemented |
TA0021 # 05 Y:2002 | 05 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $535 | $0 | Implemented |
TA0021 # 06 Y:2002 | 06 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $103 | $0 | Implemented |
TA0001 # 01 Y:2001 | 01 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $9,240 | $0 | Not Implemented |
TA0001 # 02 Y:2001 | 02 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,219 | $4,918 | Not Implemented |
TA0001 # 03 Y:2001 | 03 | 2001 | USE RADIANT HEATER FOR SPOT HEATING | $2,125 | $417 | Not Implemented |
TA0001 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $863 | $275 | Implemented |
TA0001 # 05 Y:2001 | 05 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $447 | $0 | Implemented |
TA0001 # 06 Y:2001 | 06 | 2001 | INSTALL OCCUPANCY SENSORS | $178 | $221 | Not Implemented |
TP0014 # 01 Y:2000 | 01 | 2000 | RECOVER AND REUSE WASTE MATERIAL | $12,967 | $0 | Not Implemented |
TP0014 # 02 Y:2000 | 02 | 2000 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $3,047 | $96 | Not Implemented |
TP0014 # 03 Y:2000 | 03 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,048 | $3,875 | Not Implemented |
TP0014 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $460 | $509 | Not Implemented |
TP0014 # 05 Y:2000 | 05 | 2000 | INSTALL OCCUPANCY SENSORS | $357 | $384 | Not Implemented |
TP0014 # 06 Y:2000 | 06 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $270 | $1,948 | Implemented |
TP0003 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,358 | $14,651 | Not Implemented |
TP0003 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,133 | $0 | Implemented |