IAC logo
IAC Assessment: TA0059
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TA0059
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Texas, Arlington
Assessment Year 2003
Principal Product Semiconductors&Related Devices
NAICS 334413 - Semiconductor and Related Device Manufacturing
SIC 3674 - Semiconductors And Related Devices
Sales $10,000,000-$50,000,000
# of Employees 180
Plant Area (Sq.Ft.) 44,000
Annual Production 1,000,000 Pieces
Production Hrs. Annual 4,406
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $153,908 3,063,780 kWh $0.05
Electricity Demand $49,065 6,439 kW-months/year $7.62
Electricity Fees $3,423 - $ -
Natural Gas $5,350 852 MMBtu $6.28
TOTAL ENERGY COSTS $211,746
RECOMMENDED SAVINGS* $27,401 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,775
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$9,950
Cost:
-
$9,950 196,900 - - - - $9,950
196,900
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$5,536
Cost:
$500
$5,536 109,520 - - - - $5,536
109,520
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,885
Cost:
$7,671
$3,525 69,780 $1,360 190 - - $3,525
69,780
kWh
$1,360
190
kW-months/year
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,890
Cost:
$200
$2,090 41,290 $800 112 - - $2,090
41,290
kWh
$800
112
kW-months/year
-
-
MMBtu
05: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$2,100
Cost:
$585
- - - - $2,100 334 -
-
kWh
-
-
kW-months/year
$2,100
334
MMBtu
06: 2.1132 REPAIR FAULTY LOUVERS AND DAMPERS Savings:
$2,040
Cost:
$625
$2,040 40,290 - - - - $2,040
40,290
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$27,401
Cost:
$9,581
$23,141 457,780 $2,160 302 $2,100 334 $23,141
457,780
kWh
$2,160
302
kW-months/year
$2,100
334
MMBtu
TOTAL IMPLEMENTED Savings:
$7,775
Cost:
$7,871
$5,615 111,070 $2,160 302 - - $5,615
111,070
kWh
$2,160
302
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas