Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,551
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0284 # 03 Y:2023 | 03 | 2023 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $445 | $0 | Implemented |
IC0284 # 04 Y:2023 | 04 | 2023 | INSULATE BARE EQUIPMENT | $556 | $897 | Implemented |
IC0284 # 05 Y:2023 | 05 | 2023 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $152,337 | $14,315 | Not Implemented |
IC0284 # 06 Y:2023 | 06 | 2023 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $192,600 | $121,203 | Implemented |
IC0284 # 07 Y:2023 | 07 | 2023 | TURN OFF EQUIPMENT WHEN NOT IN USE | $415 | $0 | Implemented |
IC0284 # 08 Y:2023 | 08 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $190 | $379 | Implemented |
TT0297 # 01 Y:2023 | 01 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $49,703 | $203,650 | n/a |
TT0297 # 02 Y:2023 | 02 | 2023 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,890 | $1,250 | n/a |
TT0297 # 03 Y:2023 | 03 | 2023 | INSTALL OCCUPANCY SENSORS | $11,161 | $14,500 | n/a |
TT0297 # 04 Y:2023 | 04 | 2023 | OPTIMIZE PLANT POWER FACTOR | $8,533 | $20,000 | n/a |
TT0297 # 05 Y:2023 | 05 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,428 | $1,950 | n/a |
TT0297 # 06 Y:2023 | 06 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,512 | $6,000 | n/a |
TT0297 # 07 Y:2023 | 07 | 2023 | REUSE RICH WHITE WATER IN OTHER APPLICATIONS | $1,230 | $1,820 | n/a |
TT0297 # 08 Y:2023 | 08 | 2023 | TURN OFF EQUIPMENT WHEN NOT IN USE | $735 | $750 | n/a |
SF0605 # 01 Y:2023 | 01 | 2023 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $24,945 | $4,958 | Implemented |
SF0605 # 02 Y:2023 | 02 | 2023 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $848 | $420 | Not Implemented |
SF0605 # 03 Y:2023 | 03 | 2023 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $28,696 | $38,888 | Not Implemented |
SF0605 # 04 Y:2023 | 04 | 2023 | INSTALL OCCUPANCY SENSORS | $2,116 | $10,832 | Implemented |
SF0605 # 05 Y:2023 | 05 | 2023 | INSULATE BARE EQUIPMENT | $233 | $1,287 | Implemented |
SF0605 # 06 Y:2023 | 06 | 2023 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $21,756 | $37,440 | Not Implemented |
SF0605 # 07 Y:2023 | 07 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $129,996 | $428,510 | Not Implemented |
NT0013 # 01 Y:2023 | 01 | 2023 | UPGRADE CONTROLS ON COMPRESSORS | $71,747 | $106,919 | Implemented |
NT0013 # 02 Y:2023 | 02 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,755 | $21,512 | Implemented |
NT0013 # 03 Y:2023 | 03 | 2023 | OPTIMIZE PLANT POWER FACTOR | $10,076 | $5,043 | Not Implemented |
NT0013 # 04 Y:2023 | 04 | 2023 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $49,000 | $83,421 | Implemented |