Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

390

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0108 # 05 Y:1994 05 1994 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $7,611 $26,535 Not Implemented
AS0108 # 06 Y:1994 06 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $374 $2,060 Not Implemented
CO0291 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $2,720 $2,720 Implemented
CO0291 # 03 Y:1994 03 1994 INSTALL TIMERS AND/OR THERMOSTATS $7,140 $7,690 Not Implemented
CO0291 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $780 $700 Implemented
CO0291 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $450 $1,440 Implemented
CO0291 # 06 Y:1994 06 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $440 $1,290 Not Implemented
CO0291 # 07 Y:1994 07 1994 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $370 $240 Implemented
OK0424 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,495 $12,752 Implemented
OK0424 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,237 $10,548 Implemented
OK0424 # 03 Y:1994 03 1994 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $8,534 $3,000 Implemented
OK0424 # 04 Y:1994 04 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,414 $6,750 Not Implemented
OK0424 # 05 Y:1994 05 1994 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $7,040 $2,250 Implemented
OK0424 # 06 Y:1994 06 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,472 $150 Implemented
OK0424 # 07 Y:1994 07 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,136 $0 Not Implemented