Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
68
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0344 # 01 Y:2006 | 01 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $50,956 | $1,472 | Implemented |
WV0344 # 02 Y:2006 | 02 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $41,030 | $1,000 | Implemented |
WV0344 # 03 Y:2006 | 03 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $30,895 | $15 | Not Implemented |
WV0344 # 04 Y:2006 | 04 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $22,182 | $27,387 | Implemented |
WV0344 # 05 Y:2006 | 05 | 2006 | OPTIMIZE PLANT POWER FACTOR | $18,000 | $32,500 | Implemented |
WV0344 # 06 Y:2006 | 06 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $16,147 | $26,662 | Implemented |
WV0344 # 14 Y:2006 | 14 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $217 | $100 | Not Implemented |
WV0344 # 13 Y:2006 | 13 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,197 | $1,811 | Implemented |
WV0344 # 12 Y:2006 | 12 | 2006 | ISOLATE HOT OR COLD EQUIPMENT | $1,256 | $1,500 | Not Implemented |
WV0344 # 11 Y:2006 | 11 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,355 | $436 | Implemented |
WV0344 # 10 Y:2006 | 10 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,177 | $1,896 | Implemented |
WV0344 # 09 Y:2006 | 09 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,629 | $0 | Implemented |
WV0344 # 07 Y:2006 | 07 | 2006 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $8,710 | $44 | Not Implemented |
OD0149 # 05 Y:1999 | 05 | 1999 | RECOVER AND REUSE COOLING WATER | $17,077 | $10,098 | Not Implemented |
OD0149 # 04 Y:1999 | 04 | 1999 | METER WASTE WATER | $3,741 | $4,595 | Not Implemented |
OD0149 # 03 Y:1999 | 03 | 1999 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,940 | $1,972 | Not Implemented |
OD0149 # 02 Y:1999 | 02 | 1999 | REPAIR OR REPLACE STEAM TRAPS | $10,071 | $450 | Not Implemented |
OD0149 # 01 Y:1999 | 01 | 1999 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $26,618 | $64,698 | Not Implemented |