Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
311
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0461 # 04 Y:1995 | 04 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $257 | $0 | Not Implemented |
OK0461 # 05 Y:1995 | 05 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $127 | $201 | Not Implemented |
OK0455 # 01 Y:1995 | 01 | 1995 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,900 | $25,000 | Not Implemented |
OK0455 # 02 Y:1995 | 02 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,638 | $0 | Implemented |
OK0455 # 03 Y:1995 | 03 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $913 | $128 | Implemented |
OK0455 # 04 Y:1995 | 04 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $903 | $0 | Not Implemented |
OK0455 # 05 Y:1995 | 05 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $837 | $540 | Not Implemented |
OK0455 # 06 Y:1995 | 06 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $749 | $112 | Not Implemented |
OK0455 # 07 Y:1995 | 07 | 1995 | INSTALL OCCUPANCY SENSORS | $467 | $1,100 | Implemented |
OK0455 # 08 Y:1995 | 08 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $387 | $684 | Not Implemented |
OK0455 # 09 Y:1995 | 09 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $333 | $1,186 | Implemented |
OK0453 # 01 Y:1995 | 01 | 1995 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,946 | $25,000 | Implemented |
OK0453 # 02 Y:1995 | 02 | 1995 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,563 | $189 | Implemented |
OK0453 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $703 | $2,803 | Not Implemented |
OK0453 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $416 | $554 | Implemented |
OK0453 # 05 Y:1995 | 05 | 1995 | INSTALL OCCUPANCY SENSORS | $274 | $717 | Implemented |
OK0452 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $17,658 | $12,000 | Implemented |
OK0452 # 02 Y:1994 | 02 | 1994 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $9,302 | $0 | Implemented |
OK0452 # 03 Y:1994 | 03 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $790 | $1,351 | Implemented |
OK0452 # 04 Y:1994 | 04 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $128 | $237 | Not Implemented |
OK0424 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,495 | $12,752 | Implemented |
OK0424 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,237 | $10,548 | Implemented |
OK0424 # 03 Y:1994 | 03 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $8,534 | $3,000 | Implemented |
OK0424 # 04 Y:1994 | 04 | 1994 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,414 | $6,750 | Not Implemented |
OK0424 # 05 Y:1994 | 05 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,040 | $2,250 | Implemented |