Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

76

matching recommendations
Reset
SIC 362 Electrical Industrial Apparatus
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0129 # 04 Y:1995 04 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $27,054 $29,890 Implemented
SD0129 # 05 Y:1995 05 1995 INSTALL OCCUPANCY SENSORS $1,675 $2,002 Implemented
SD0104 # 04 Y:1995 04 1995 RECOVER WASTE HEAT FROM EQUIPMENT $83,952 $150,000 Not Implemented
SD0104 # 09 Y:1995 09 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $13,450 $17,980 Implemented
SD0104 # 07 Y:1995 07 1995 INSTALL TURBULATORS $1,618 $1,600 Not Implemented
SD0104 # 06 Y:1995 06 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $4,248 $3,000 Not Implemented
SD0104 # 05 Y:1995 05 1995 ISOLATE HOT OR COLD EQUIPMENT $890 $0 Not Implemented
SD0104 # 03 Y:1995 03 1995 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $3,356 $3,400 Not Implemented
SD0104 # 02 Y:1995 02 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,382 $9,800 Not Implemented
SD0104 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $24,474 $22,100 Implemented
SD0104 # 08 Y:1995 08 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $25,523 $23,647 Implemented
SD0025 # 07 Y:1992 07 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $785 $925 Not Implemented
SD0025 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $130 $900 Implemented
SD0025 # 02 Y:1992 02 1992 TURN OFF EQUIPMENT WHEN NOT IN USE $710 $120 Implemented
SD0025 # 03 Y:1992 03 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,866 $2,000 Implemented
SD0025 # 04 Y:1992 04 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $582 $45 Not Implemented
SD0025 # 05 Y:1992 05 1992 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,093 $4,450 Implemented
SD0025 # 06 Y:1992 06 1992 INSULATE BARE EQUIPMENT $338 $77 Not Implemented
SD0025 # 08 Y:1992 08 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,781 $1,200 Not Implemented
SD0025 # 09 Y:1992 09 1992 INSTALL SET-BACK TIMERS $2,785 $3,240 Not Implemented
SD0025 # 10 Y:1992 10 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,471 $1,980 Not Implemented
SD0018 # 06 Y:1992 06 1992 SCHEDULE BAKING TIMES OF SMALL AND LARGE COMPONENTS $417 $0 Implemented
SD0018 # 04 Y:1992 04 1992 RECOVER WASTE HEAT FROM EQUIPMENT $1,764 $551 Implemented
SD0018 # 02 Y:1992 02 1992 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $870 $620 Implemented
SD0018 # 08 Y:1992 08 1992 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,830 $600 Implemented