IAC logo
IAC Assessment: SD0104
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SD0104
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1995
Principal Product Composite Materials
NAICS n/a
SIC 3624 - Carbon And Graphite Products
Sales $50,000,000-$100,000,000
# of Employees 200
Plant Area (Sq.Ft.) 330,000
Annual Production 600,000 Pounds
Production Hrs. Annual 6,756
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $915,770 11,335,287 kWh $0.08
Natural Gas $186,890 49,990 MMBtu $3.74
TOTAL ENERGY COSTS $1,102,660
RECOMMENDED SAVINGS* $161,893 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $63,447
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$24,474
Cost:
$22,100
$24,474 303,048 - - $24,474
303,048
kWh
-
-
MMBtu
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,382
Cost:
$9,800
$4,382 54,220 - - $4,382
54,220
kWh
-
-
MMBtu
03: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$3,356
Cost:
$3,400
- - $3,356 898 -
-
kWh
$3,356
898
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$83,952
Cost:
$150,000
- - $83,952 22,447 -
-
kWh
$83,952
22,447
MMBtu
05: 2.2522 ISOLATE HOT OR COLD EQUIPMENT Savings:
$890
Cost:
-
$890 21,395 - - $890
21,395
kWh
-
-
MMBtu
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$4,248
Cost:
$3,000
$4,248 52,462 - - $4,248
52,462
kWh
-
-
MMBtu
07: 2.1222 INSTALL TURBULATORS Savings:
$1,618
Cost:
$1,600
- - $1,618 433 -
-
kWh
$1,618
433
MMBtu
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$25,523
Cost:
$23,647
$25,523 296,014 - - $25,523
296,014
kWh
-
-
MMBtu
09: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$13,450
Cost:
$17,980
$13,450 148,300 - - $13,450
148,300
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$161,893
Cost:
$231,527
$72,967 875,439 $88,926 23,778 $72,967
875,439
kWh
$88,926
23,778
MMBtu
TOTAL IMPLEMENTED Savings:
$63,447
Cost:
$63,727
$63,447 747,362 - - $63,447
747,362
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas