Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,310
matching recommendationsSIC | 362 | Electrical Industrial Apparatus |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0025 # 02 Y:1992 | 02 | 1992 | TURN OFF EQUIPMENT WHEN NOT IN USE | $710 | $120 | Implemented |
SD0025 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,866 | $2,000 | Implemented |
SD0025 # 04 Y:1992 | 04 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $582 | $45 | Not Implemented |
SD0025 # 05 Y:1992 | 05 | 1992 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,093 | $4,450 | Implemented |
SD0025 # 06 Y:1992 | 06 | 1992 | INSULATE BARE EQUIPMENT | $338 | $77 | Not Implemented |
SD0025 # 07 Y:1992 | 07 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $785 | $925 | Not Implemented |
SD0025 # 08 Y:1992 | 08 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,781 | $1,200 | Not Implemented |
SD0025 # 09 Y:1992 | 09 | 1992 | INSTALL SET-BACK TIMERS | $2,785 | $3,240 | Not Implemented |
SD0025 # 10 Y:1992 | 10 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,471 | $1,980 | Not Implemented |
SD0018 # 12 Y:1992 | 12 | 1992 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $14,051 | $2,500 | Implemented |
SD0018 # 11 Y:1992 | 11 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $4,343 | $10,788 | Implemented |
SD0018 # 10 Y:1992 | 10 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $593 | $0 | Implemented |
SD0018 # 09 Y:1992 | 09 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,375 | $3,300 | Not Implemented |
SD0018 # 08 Y:1992 | 08 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,830 | $600 | Implemented |
SD0018 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $3,338 | $7,500 | Implemented |
SD0018 # 06 Y:1992 | 06 | 1992 | SCHEDULE BAKING TIMES OF SMALL AND LARGE COMPONENTS | $417 | $0 | Implemented |
SD0018 # 05 Y:1992 | 05 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $635 | $729 | Not Implemented |
SD0018 # 04 Y:1992 | 04 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,764 | $551 | Implemented |
SD0018 # 03 Y:1992 | 03 | 1992 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,562 | $120 | Implemented |
SD0018 # 02 Y:1992 | 02 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $870 | $620 | Implemented |
SD0018 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $92 | $233 | Implemented |
UD0367 # 02 Y:1992 | 02 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,207 | $400 | Not Implemented |
UD0367 # 01 Y:1992 | 01 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $727 | $0 | Not Implemented |
UD0367 # 03 Y:1992 | 03 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $4,588 | $1,800 | Not Implemented |
SD0010 # 09 Y:1991 | 09 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,188 | $18,000 | Not Implemented |