Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
403
matching recommendationsSIC | 363 | Household Appliances |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0298 # 03 Y:1987 | 03 | 1987 | CLOSE OFF UNNEEDED STEAM LINES | $2,873 | $0 | Not Implemented |
TN0298 # 04 Y:1987 | 04 | 1987 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $2,202 | $2,107 | Not Implemented |
TN0298 # 05 Y:1987 | 05 | 1987 | USE MINIMUM STEAM OPERATING PRESSURE | $2,580 | $0 | Not Implemented |
TN0298 # 06 Y:1987 | 06 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,865 | $1,500 | Implemented |
TN0298 # 07 Y:1987 | 07 | 1987 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $232 | $92 | Not Implemented |
TN0298 # 08 Y:1987 | 08 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $715 | $0 | Implemented |
TN0280 # 01 Y:1986 | 01 | 1986 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $3,536 | $815 | Implemented |
TN0280 # 02 Y:1986 | 02 | 1986 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,530 | $9,916 | Not Implemented |
TN0280 # 03 Y:1986 | 03 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,837 | $10,750 | Implemented |
TN0280 # 04 Y:1986 | 04 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,539 | $2,750 | Implemented |
TN0280 # 05 Y:1986 | 05 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $747 | $0 | Not Implemented |
TN0280 # 06 Y:1986 | 06 | 1986 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $335 | $445 | Not Implemented |
TN0280 # 07 Y:1986 | 07 | 1986 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $259 | $275 | Implemented |
TN0275 # 01 Y:1986 | 01 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $5,736 | $3,400 | Not Implemented |
TN0275 # 02 Y:1986 | 02 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,746 | $10,000 | Not Implemented |
TN0275 # 03 Y:1986 | 03 | 1986 | REDESIGN PROCESS | $6,722 | $17,900 | Not Implemented |
TN0275 # 04 Y:1986 | 04 | 1986 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $5,462 | $12,675 | Not Implemented |
TN0275 # 05 Y:1986 | 05 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,628 | $375 | Implemented |
TN0275 # 06 Y:1986 | 06 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,571 | $1,300 | Implemented |
KU0190 # 01 Y:1986 | 01 | 1986 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,383 | $50 | Implemented |
KU0190 # 02 Y:1986 | 02 | 1986 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $215 | $0 | Implemented |
KU0190 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,038 | $1,510 | Implemented |
KU0190 # 04 Y:1986 | 04 | 1986 | IMPROVE LUBRICATION PRACTICES | $1,009 | $600 | Not Implemented |
KU0190 # 05 Y:1986 | 05 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $658 | $120 | Implemented |
KU0190 # 06 Y:1986 | 06 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $673 | $10 | Implemented |