Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1986
Principal Product APPLIANCE HEAT ELEMENTS
NAICS n/a
SIC 3634 - Electric Housewares And Fans
Sales $10,000,000-$50,000,000
# of Employees 260
Plant Area (Sq.Ft.) 0
Annual Production 5,000,000 Pieces
Production Hrs. Annual 4,250
Location (State) TN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $245,352 5,252,052 kWh $0.05
Natural Gas $56,635 12,428 MMBtu $4.56
TOTAL ENERGY COSTS $301,987
RECOMMENDED SAVINGS* $28,865 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $9,199
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$5,736
Cost:
$3,400
- - $5,736 1,258 -
-
kWh
$5,736
1,258
MMBtu
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$1,746
Cost:
$10,000
- - $1,746 383 -
-
kWh
$1,746
383
MMBtu
03: 2.5194 REDESIGN PROCESS Savings:
$6,722
Cost:
$17,900
$6,722 143,904 - - $6,722
143,904
kWh
-
-
MMBtu
04: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS Savings:
$5,462
Cost:
$12,675
$5,462 116,940 - - $5,462
116,940
kWh
-
-
MMBtu
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,628
Cost:
$375
$2,628 56,272 - - $2,628
56,272
kWh
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,571
Cost:
$1,300
$6,571 140,680 - - $6,571
140,680
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$28,865
Cost:
$45,650
$21,383 457,796 $7,482 1,641 $21,383
457,796
kWh
$7,482
1,641
MMBtu
TOTAL IMPLEMENTED Savings:
$9,199
Cost:
$1,675
$9,199 196,952 - - $9,199
196,952
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas