Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

42

matching recommendations
Reset
SIC 3633 Household Laundry Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0524 # 07 Y:1997 07 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $816 $0 Not Implemented
OK0524 # 06 Y:1997 06 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,056 $0 Not Implemented
OK0524 # 05 Y:1997 05 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,329 $90 Not Implemented
OK0524 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,530 $80,000 Not Implemented
OK0524 # 03 Y:1997 03 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $16,057 $65,478 Not Implemented
OK0524 # 01 Y:1997 01 1997 $86,855 $175,000 Not Implemented
IA0015 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,595 $0 Implemented
IA0015 # 07 Y:1991 07 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,300 $4,278 Implemented
IA0015 # 06 Y:1991 06 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,851 $100 Implemented
IA0015 # 05 Y:1991 05 1991 RECOVER WASTE HEAT FROM EQUIPMENT $3,896 $5,370 Implemented
IA0015 # 04 Y:1991 04 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,364 $8,000 Implemented
IA0015 # 03 Y:1991 03 1991 INSTALL SET-BACK TIMERS $440 $200 Implemented
IA0015 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $846 $1,980 Implemented
LT0017 # 06 Y:1985 06 1985 USE DEMAND CONTROLLER OR LOAD SHEDDER $6,190 $10,000 Implemented
LT0017 # 05 Y:1985 05 1985 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $569 $600 Not Implemented
LT0017 # 04 Y:1985 04 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,960 $13,000 Implemented
LT0017 # 03 Y:1985 03 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,540 $150 Implemented