Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 364 | Electric Lighting And Wiring Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0749 # 12 Y:2015 | 12 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,079 | $100 | Implemented |
MA0749 # 11 Y:2015 | 11 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,227 | $1,013 | Not Implemented |
MA0749 # 10 Y:2015 | 10 | 2015 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $1,592 | $500 | Not Implemented |
MA0749 # 09 Y:2015 | 09 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,372 | $1,000 | Implemented |
MA0749 # 08 Y:2015 | 08 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,495 | $500 | Not Implemented |
MA0749 # 07 Y:2015 | 07 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,067 | $3,000 | Implemented |
MA0749 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,856 | $24,500 | Implemented |
MA0749 # 01 Y:2015 | 01 | 2015 | REDUCE VENTILATION AIR | $30,757 | $20,400 | Implemented |
MA0749 # 02 Y:2015 | 02 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $24,207 | $1,000 | Implemented |
MA0749 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,980 | $3,330 | Implemented |
MA0749 # 04 Y:2015 | 04 | 2015 | OPTIMIZE PLANT POWER FACTOR | $10,366 | $25,300 | Not Implemented |
MA0749 # 05 Y:2015 | 05 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $8,523 | $1,000 | Not Implemented |
MA0694 # 02 Y:2012 | 02 | 2012 | REDUCE VENTILATION AIR | $7,473 | $0 | Not Implemented |
MA0694 # 08 Y:2012 | 08 | 2012 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $253 | $900 | Not Implemented |
MA0694 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $503 | $900 | Implemented |
MA0694 # 06 Y:2012 | 06 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $1,515 | $3,410 | Not Implemented |
MA0694 # 05 Y:2012 | 05 | 2012 | INSULATE BARE EQUIPMENT | $2,300 | $16,608 | Implemented |
MA0694 # 04 Y:2012 | 04 | 2012 | INSULATE BARE EQUIPMENT | $3,042 | $665 | Not Implemented |
MA0694 # 03 Y:2012 | 03 | 2012 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $5,619 | $0 | Implemented |
MA0694 # 01 Y:2012 | 01 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $12,023 | $500 | Implemented |
MA0397 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,044 | $600 | Implemented |
MA0397 # 02 Y:1997 | 02 | 1997 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $3,025 | $200 | Implemented |
MA0397 # 03 Y:1997 | 03 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,200 | $0 | Implemented |
MA0397 # 04 Y:1997 | 04 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $874 | $681 | Not Implemented |
MA0397 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $790 | $404 | Implemented |