Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1071 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,382 | $61,013 | Implemented |
OK1071 # 02 Y:2022 | 02 | 2022 | REPLACE TREATED WATER WITH WELL / SURFACE WATER | $12,657 | $10,000 | Not Implemented |
OK1071 # 03 Y:2022 | 03 | 2022 | INSTALL SPECTRAL REFLECTORS / DELAMP | $9,419 | $0 | Not Implemented |
OK1071 # 04 Y:2022 | 04 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,640 | $0 | Not Implemented |
OK0991 # 02 Y:2018 | 02 | 2018 | OPTIMIZE PLANT POWER FACTOR | $7,248 | $14,404 | Not Implemented |
OK0991 # 03 Y:2018 | 03 | 2018 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,813 | $0 | Not Implemented |
OK0991 # 04 Y:2018 | 04 | 2018 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $5,577 | $1,015 | Implemented |
OK0991 # 05 Y:2018 | 05 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,710 | $536 | Implemented |
OK0991 # 06 Y:2018 | 06 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $724 | $0 | Implemented |
OK0991 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,462 | $17,053 | Implemented |
OK0963 # 06 Y:2017 | 06 | 2017 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $4,116 | $1,182 | Implemented |
OK0963 # 05 Y:2017 | 05 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $272 | $0 | Implemented |
OK0963 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,783 | $62,981 | Not Implemented |
OK0963 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,310 | $5,608 | Not Implemented |
OK0963 # 03 Y:2017 | 03 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,937 | $38,220 | Implemented |
OK0963 # 04 Y:2017 | 04 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,699 | $12,090 | Not Implemented |
KU0179 # 06 Y:1985 | 06 | 1985 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $174 | $0 | Implemented |
KU0179 # 05 Y:1985 | 05 | 1985 | COVER OPEN TANKS | $279 | $60 | Implemented |
KU0179 # 04 Y:1985 | 04 | 1985 | USE OPTIMUM THICKNESS INSULATION | $730 | $1,138 | Not Implemented |
KU0179 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $990 | $1,450 | Implemented |
KU0179 # 02 Y:1985 | 02 | 1985 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $1,693 | $764 | Not Implemented |
KU0179 # 01 Y:1985 | 01 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,642 | $500 | Implemented |
KU0160 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,662 | $2,000 | Implemented |
KU0160 # 06 Y:1985 | 06 | 1985 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $433 | $200 | Not Implemented |
KU0160 # 02 Y:1985 | 02 | 1985 | INSULATE BARE EQUIPMENT | $1,982 | $900 | Implemented |