Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,199

matching recommendations
Reset
SIC 367 Electronic Components And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0315 # 03 Y:1994 03 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,070 $1,770 Implemented
CO0315 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,010 $5,310 Implemented
CO0315 # 05 Y:1994 05 1994 RECOVER WASTE HEAT FROM EQUIPMENT $630 $650 Not Implemented
CO0315 # 06 Y:1994 06 1994 UTILIZE A LESS EXPENSIVE COOLING METHOD $410 $2,000 Not Implemented
SD0095 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,578 $3,900 Implemented
SD0095 # 02 Y:1994 02 1994 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $12,261 $82,000 Not Implemented
SD0095 # 03 Y:1994 03 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $474 $1,400 Implemented
SD0095 # 04 Y:1994 04 1994 INSULATE BARE EQUIPMENT $582 $750 Implemented
SD0095 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $157 $720 Implemented
SD0095 # 06 Y:1994 06 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $245 $500 Implemented
SD0095 # 07 Y:1994 07 1994 INSTALL OCCUPANCY SENSORS $1,484 $2,520 Implemented
SD0095 # 08 Y:1994 08 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $793 $114 Implemented
SD0095 # 09 Y:1994 09 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $383 $280 Implemented
CO0310 # 01 Y:1994 01 1994 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $7,150 $0 Not Implemented
CO0310 # 02 Y:1994 02 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,900 $3,810 Not Implemented
CO0310 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,070 $6,820 Implemented
CO0310 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,880 $1,720 Not Implemented
CO0310 # 05 Y:1994 05 1994 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $1,840 $0 Implemented
CO0310 # 06 Y:1994 06 1994 REDUCE VENTILATION AIR $850 $550 Implemented
CO0310 # 07 Y:1994 07 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $440 $730 Implemented
CO0310 # 08 Y:1994 08 1994 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $410 $90 Implemented
SD0092 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $338 $350 Implemented
SD0092 # 02 Y:1994 02 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $579 $20 Implemented
SD0092 # 03 Y:1994 03 1994 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $513 $320 Implemented
SD0092 # 04 Y:1994 04 1994 INSTALL TIMERS AND/OR THERMOSTATS $10,389 $1,800 Implemented