IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

14

matching recommendations
Reset
SIC 367 Electronic Components And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0100 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $824 $3,754 Not Implemented
OD0100 # 02 Y:1997 02 1997 INSTALL TIMERS AND/OR THERMOSTATS $503 $0 Implemented
OD0100 # 03 Y:1997 03 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $289 $0 Not Implemented
OD0100 # 04 Y:1997 04 1997 MINIMIZE WATER USAGE $213 $90 Not Implemented
OD0100 # 05 Y:1997 05 1997 INSTALL AUTOMATIC PACKING EQUIPMENT $2,016 $1,160 Not Implemented
OD0054 # 01 Y:1996 01 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,378 $6,136 Implemented
OD0054 # 02 Y:1996 02 1996 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $24,554 $66,950 Not Implemented
OD0054 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,848 $8,027 Not Implemented
OD0054 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,690 $2,976 Implemented
OD0054 # 05 Y:1996 05 1996 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $8,786 $1,296 Implemented
OD0054 # 06 Y:1996 06 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $465 $400 Implemented
OD0054 # 07 Y:1996 07 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,400 $500 Implemented
OD0054 # 08 Y:1996 08 1996 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,088 $7,873 Not Implemented
OD0054 # 09 Y:1996 09 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $15,938 $0 Not Implemented