IAC logo
IAC Assessment: OD0054
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OD0054
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Old Dominion Univ.
Assessment Year 1996
Principal Product Electronic Components
NAICS n/a
SIC 3679 - Electronic Components, Nec
Sales $50,000,000-$100,000,000
# of Employees 500
Plant Area (Sq.Ft.) 185,000
Annual Production 200,000 Pieces
Production Hrs. Annual 4,080
Location (State) VA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $180,465 10,209,555 kWh $0.02
Electricity Demand $286,664 21,545 kW-months/year $13.31
Electricity Fees $234,170 - $ -
Natural Gas $121,489 35,387 MMBtu $3.43
TOTAL ENERGY COSTS $859,978
RECOMMENDED SAVINGS* $87,147 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $22,719
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Solid Waste (haz) Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Solid Waste (haz)
$ kWh $ kW-months/year $ MMBtu $ lb $ lb
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$9,378
Cost:
$6,136
$9,378 136,577 - - - - - - - - $9,378
136,577
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
-
-
lb
02: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$24,554
Cost:
$66,950
$24,554 362,251 - - - - - - - - $24,554
362,251
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
-
-
lb
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$14,848
Cost:
$8,027
$4,533 256,155 $10,315 775 - - - - - - $4,533
256,155
kWh
$10,315
775
kW-months/year
-
-
MMBtu
-
-
lb
-
-
lb
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,690
Cost:
$2,976
$886 50,117 $1,804 69 - - - - - - $886
50,117
kWh
$1,804
69
kW-months/year
-
-
MMBtu
-
-
lb
-
-
lb
05: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY Savings:
$8,786
Cost:
$1,296
$4,329 244,725 $4,457 335 - - - - - - $4,329
244,725
kWh
$4,457
335
kW-months/year
-
-
MMBtu
-
-
lb
-
-
lb
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$465
Cost:
$400
$465 26,377 - - - - - - - - $465
26,377
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
-
-
lb
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,400
Cost:
$500
- - - - $1,400 408 - - - - -
-
kWh
-
-
kW-months/year
$1,400
408
MMBtu
-
-
lb
-
-
lb
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$9,088
Cost:
$7,873
- - - - $9,088 2,647 - - - - -
-
kWh
-
-
kW-months/year
$9,088
2,647
MMBtu
-
-
lb
-
-
lb
09: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$15,938
Cost:
-
- - - - - - $1,200 1,200,000 $14,738 15,000 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$1,200
1,200,000
lb
$14,738
15,000
lb
TOTAL RECOMMENDED Savings:
$87,147
Cost:
$94,158
$44,145 1,076,202 $16,576 1,179 $10,488 3,055 $1,200 1,200,000 $14,738 15,000 $44,145
1,076,202
kWh
$16,576
1,179
kW-months/year
$10,488
3,055
MMBtu
$1,200
1,200,000
lb
$14,738
15,000
lb
TOTAL IMPLEMENTED Savings:
$22,719
Cost:
$11,308
$15,058 457,796 $6,261 404 $1,400 408 - - - - $15,058
457,796
kWh
$6,261
404
kW-months/year
$1,400
408
MMBtu
-
-
lb
-
-
lb
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ lb $ lb
Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Solid Waste (haz) Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Solid Waste (haz)