Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | Electronic Components |
NAICS | n/a |
SIC | 3679 - Electronic Components, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 185,000 |
Annual Production | 200,000 Pieces |
Production Hrs. Annual | 4,080 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $180,465 | 10,209,555 | kWh | $0.02 |
Electricity Demand | $286,664 | 21,545 | kW-months/year | $13.31 |
Electricity Fees | $234,170 | - | $ | - |
Natural Gas | $121,489 | 35,387 | MMBtu | $3.43 |
TOTAL ENERGY COSTS | $859,978 | |||
RECOMMENDED SAVINGS* | $87,147 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,719 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Solid Waste (haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Solid Waste (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $9,378 Cost: $6,136 |
$9,378 | 136,577 | - | - | - | - | - | - | - | - |
$9,378 136,577 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $24,554 Cost: $66,950 |
$24,554 | 362,251 | - | - | - | - | - | - | - | - |
$24,554 362,251 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $14,848 Cost: $8,027 |
$4,533 | 256,155 | $10,315 | 775 | - | - | - | - | - | - |
$4,533 256,155 kWh |
$10,315 775 kW-months/year |
- - MMBtu |
- - lb |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,690 Cost: $2,976 |
$886 | 50,117 | $1,804 | 69 | - | - | - | - | - | - |
$886 50,117 kWh |
$1,804 69 kW-months/year |
- - MMBtu |
- - lb |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $8,786 Cost: $1,296 |
$4,329 | 244,725 | $4,457 | 335 | - | - | - | - | - | - |
$4,329 244,725 kWh |
$4,457 335 kW-months/year |
- - MMBtu |
- - lb |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $465 Cost: $400 |
$465 | 26,377 | - | - | - | - | - | - | - | - |
$465 26,377 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,400 Cost: $500 |
- | - | - | - | $1,400 | 408 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,400 408 MMBtu |
- - lb |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $9,088 Cost: $7,873 |
- | - | - | - | $9,088 | 2,647 | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,088 2,647 MMBtu |
- - lb |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $15,938 Cost: - |
- | - | - | - | - | - | $1,200 | 1,200,000 | $14,738 | 15,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,200 1,200,000 lb |
$14,738 15,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $87,147 Cost: $94,158 |
$44,145 | 1,076,202 | $16,576 | 1,179 | $10,488 | 3,055 | $1,200 | 1,200,000 | $14,738 | 15,000 | $44,145 1,076,202 kWh |
$16,576 1,179 kW-months/year |
$10,488 3,055 MMBtu |
$1,200 1,200,000 lb |
$14,738 15,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,719 Cost: $11,308 |
$15,058 | 457,796 | $6,261 | 404 | $1,400 | 408 | - | - | - | - | $15,058 457,796 kWh |
$6,261 404 kW-months/year |
$1,400 408 MMBtu |
- - lb |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Solid Waste (haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Solid Waste (haz) |