Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

13

matching recommendations
Reset
SIC 3672 Printed Circuit Boards
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0826 # 01 Y:2021 01 2021 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $27,883 $250,000 Not Implemented
MA0826 # 02 Y:2021 02 2021 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,639 $14,650 Not Implemented
MA0826 # 03 Y:2021 03 2021 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,447 $10,800 Not Implemented
MA0826 # 04 Y:2021 04 2021 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $979 $1,631 Implemented
MA0826 # 05 Y:2021 05 2021 TURN OFF EQUIPMENT WHEN NOT IN USE $552 $250 Not Implemented
MA0826 # 06 Y:2021 06 2021 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $551 $1,450 Implemented
MA0826 # 07 Y:2021 07 2021 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $323 $625 Not Implemented
MA0168 # 01 Y:1989 01 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $14,558 $10,000 Not Implemented
MA0168 # 02 Y:1989 02 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,218 $0 Implemented
MA0168 # 03 Y:1989 03 1989 INSTALL SET-BACK TIMERS $228 $195 Not Implemented
MA0168 # 04 Y:1989 04 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,362 $570 Implemented
MA0168 # 05 Y:1989 05 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $475 $305 Not Implemented
MA0168 # 06 Y:1989 06 1989 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,664 $2,700 Not Implemented