Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsSIC | 3679 | Electronic Components, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0096 # 02 Y:1993 | 02 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,441 | $0 | Implemented |
AS0096 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $369 | $497 | Not Implemented |
AS0096 # 04 Y:1993 | 04 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $628 | $0 | Not Implemented |
AS0096 # 05 Y:1993 | 05 | 1993 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,006 | $7,200 | Implemented |
AS0096 # 06 Y:1993 | 06 | 1993 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,455 | $9,000 | Not Implemented |
AS0096 # 07 Y:1993 | 07 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $516 | $200 | Not Implemented |
AS0096 # 08 Y:1993 | 08 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $909 | $500 | Implemented |
AS0096 # 09 Y:1993 | 09 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $792 | $150 | Not Implemented |
AS0096 # 10 Y:1993 | 10 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,451 | $4,000 | Not Implemented |
AS0096 # 11 Y:1993 | 11 | 1993 | ISOLATE HOT OR COLD EQUIPMENT | $1,577 | $300 | Implemented |
AS0096 # 12 Y:1993 | 12 | 1993 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $178 | $100 | Implemented |
AS0096 # 01 Y:1993 | 01 | 1993 | ADD AREA LIGHTING SWITCHES | $1,219 | $2,012 | Implemented |
UD0405 # 01 Y:1993 | 01 | 1993 | UPGRADE CONTROLS ON COMPRESSORS | $2,213 | $100 | Implemented |
UD0405 # 04 Y:1993 | 04 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $548 | $1,000 | Implemented |
UD0405 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,176 | $2,511 | Implemented |
UD0405 # 02 Y:1993 | 02 | 1993 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $2,743 | $2,000 | Implemented |
WI0177 # 09 Y:1993 | 09 | 1993 | INSULATE BARE EQUIPMENT | $180 | $43 | Not Implemented |
WI0177 # 08 Y:1993 | 08 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $231 | $60 | Implemented |
WI0177 # 07 Y:1993 | 07 | 1993 | CONSIDER THREE OR FOUR DAYS AROUND-THE-CLOCK OPERATION RATHER THAN ONE OR TWO SHIFTS PER DAY | $852 | $0 | Implemented |
WI0177 # 06 Y:1993 | 06 | 1993 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $1,065 | $4,600 | Not Implemented |
WI0177 # 05 Y:1993 | 05 | 1993 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,662 | $400 | Not Implemented |
WI0177 # 04 Y:1993 | 04 | 1993 | USE PHOTOCELL CONTROLS | $175 | $400 | Implemented |
WI0177 # 03 Y:1993 | 03 | 1993 | INSTALL OCCUPANCY SENSORS | $797 | $1,100 | Implemented |
WI0177 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,476 | $4,167 | Implemented |
WI0177 # 01 Y:1993 | 01 | 1993 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,682 | $5,600 | Not Implemented |