Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
278
matching recommendationsSIC | 3691 | Storage Batteries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0294 # 03 Y:1989 | 03 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $7,667 | $8,200 | Not Implemented |
KU0294 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,153 | $4,100 | Implemented |
KU0294 # 05 Y:1989 | 05 | 1989 | INSULATE BARE EQUIPMENT | $1,104 | $600 | Implemented |
KU0294 # 06 Y:1989 | 06 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $526 | $200 | Implemented |
KU0294 # 07 Y:1989 | 07 | 1989 | TURN OFF EQUIPMENT WHEN NOT IN USE | $579 | $0 | Implemented |
KU0288 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,193 | $500 | Implemented |
KU0288 # 02 Y:1989 | 02 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,064 | $1,200 | Implemented |
KU0288 # 03 Y:1989 | 03 | 1989 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $643 | $2,900 | Implemented |
KU0288 # 04 Y:1989 | 04 | 1989 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $584 | $1,800 | Not Implemented |
LT0124 # 01 Y:1988 | 01 | 1988 | COVER OPEN TANKS | $64,900 | $12,000 | Implemented |
LT0124 # 02 Y:1988 | 02 | 1988 | USE OPTIMUM THICKNESS INSULATION | $9,378 | $2,760 | Implemented |
LT0124 # 03 Y:1988 | 03 | 1988 | REDESIGN PROCESS | $6,995 | $0 | Implemented |
LT0124 # 04 Y:1988 | 04 | 1988 | USE OPTIMUM TEMPERATURE | $3,576 | $0 | Implemented |
LT0124 # 05 Y:1988 | 05 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,660 | $2,693 | Implemented |
LT0124 # 06 Y:1988 | 06 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,640 | $0 | Implemented |
LT0124 # 07 Y:1988 | 07 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,049 | $453 | Implemented |
LT0124 # 08 Y:1988 | 08 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $247 | $55 | Implemented |
LT0124 # 09 Y:1988 | 09 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $979 | $1,050 | Implemented |
OR0002 # 01 Y:1987 | 01 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,190 | $300 | Implemented |
OR0002 # 02 Y:1987 | 02 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,568 | $550 | Not Implemented |
OR0002 # 03 Y:1987 | 03 | 1987 | MINIMIZE WATER USAGE | $1,082 | $300 | Not Implemented |
OR0002 # 04 Y:1987 | 04 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,563 | $4,730 | Not Implemented |
OR0002 # 05 Y:1987 | 05 | 1987 | OPTIMIZE PLANT POWER FACTOR | $4,962 | $7,398 | Implemented |
OR0002 # 06 Y:1987 | 06 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $543 | $970 | Implemented |
AT0059 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $447 | $612 | Implemented |