Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,513
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0387 # 03 Y:2015 | 03 | 2015 | INSULATE BARE EQUIPMENT | $988 | $858 | Not Implemented |
SU0387 # 04 Y:2015 | 04 | 2015 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $15,923 | $25,000 | Not Implemented |
SU0387 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $776 | $1,546 | Not Implemented |
SU0387 # 06 Y:2015 | 06 | 2015 | MAKE A NEW BY-PRODUCT | $20,522 | $100,000 | Not Implemented |
MZ0175 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,580 | $25,425 | Not Implemented |
MZ0175 # 02 Y:2015 | 02 | 2015 | INSTALL OCCUPANCY SENSORS | $1,344 | $1,800 | Not Implemented |
MZ0175 # 03 Y:2015 | 03 | 2015 | INSTALL OCCUPANCY SENSORS | $953 | $1,500 | Not Implemented |
MZ0175 # 04 Y:2015 | 04 | 2015 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,198 | $0 | Not Implemented |
MZ0175 # 05 Y:2015 | 05 | 2015 | INSULATE BARE EQUIPMENT | $3,987 | $14,400 | Not Implemented |
MI0278 # 01 Y:2015 | 01 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $103,740 | $220,000 | Not Implemented |
MI0278 # 02 Y:2015 | 02 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $94,012 | $102,610 | Not Implemented |
MI0278 # 03 Y:2015 | 03 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $45,923 | $79,106 | Implemented |
MI0278 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,431 | $9,248 | Implemented |
MI0278 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,235 | $1,660 | Implemented |
MI0278 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $4,706 | $2,901 | Implemented |
MI0278 # 07 Y:2015 | 07 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,804 | $480 | Implemented |
MI0278 # 08 Y:2015 | 08 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,391 | $8,360 | Implemented |
MI0278 # 09 Y:2015 | 09 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,181 | $40 | Implemented |
MI0278 # 10 Y:2015 | 10 | 2015 | USE OPTIMUM THICKNESS INSULATION | $711 | $610 | Implemented |
MI0278 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $671 | $1,880 | Implemented |
MZ0170 # 01 Y:2015 | 01 | 2015 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $56,753 | $214,172 | Not Implemented |
MZ0170 # 02 Y:2015 | 02 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $4,189 | $17,018 | Not Implemented |
MZ0170 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,117 | $0 | Not Implemented |
MZ0170 # 04 Y:2015 | 04 | 2015 | CONDENSE OPERATION INTO ONE BUILDING | $11,328 | $0 | Not Implemented |
MA0744 # 01 Y:2015 | 01 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,197 | $27,500 | Not Implemented |