Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
194
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0088 # 03 Y:1987 | 03 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,180 | $1,020 | Not Implemented |
CO0088 # 04 Y:1987 | 04 | 1987 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $9,431 | $3,200 | Implemented |
CO0088 # 05 Y:1987 | 05 | 1987 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,852 | $5,000 | Not Implemented |
CO0088 # 06 Y:1987 | 06 | 1987 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $13,610 | $30,000 | Not Implemented |
CO0088 # 07 Y:1987 | 07 | 1987 | USE RADIANT HEATER FOR SPOT HEATING | $11,670 | $40,000 | Not Implemented |
CO0088 # 08 Y:1987 | 08 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $982 | $500 | Implemented |
CO0088 # 09 Y:1987 | 09 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,794 | $500 | Implemented |
CO0088 # 10 Y:1987 | 10 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,575 | $6,500 | Not Implemented |
CO0088 # 11 Y:1987 | 11 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,380 | $2,000 | Implemented |
CO0088 # 12 Y:1987 | 12 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,873 | $720 | Implemented |
CO0050 # 01 Y:1985 | 01 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,161 | $6,500 | Not Implemented |
CO0050 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $16,221 | $2,791 | Implemented |
CO0050 # 03 Y:1985 | 03 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $888 | $200 | Implemented |
CO0050 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $159 | $200 | Implemented |
CO0050 # 05 Y:1985 | 05 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,313 | $1,600 | Implemented |
CO0050 # 06 Y:1985 | 06 | 1985 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $6,022 | $1,570 | Implemented |
CO0050 # 07 Y:1985 | 07 | 1985 | INSTALL STORM WINDOWS AND DOORS | $985 | $750 | Not Implemented |
CO0050 # 08 Y:1985 | 08 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,212 | $800 | Implemented |
CO0050 # 09 Y:1985 | 09 | 1985 | INSTALL TURBULATORS | $793 | $1,000 | Not Implemented |
CO0050 # 10 Y:1985 | 10 | 1985 | IMPROVE LUBRICATION PRACTICES | $157 | $0 | Not Implemented |
CO0050 # 11 Y:1985 | 11 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $825 | $3,564 | Not Implemented |
CO0036 # 01 Y:1985 | 01 | 1985 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $179 | $0 | Implemented |
CO0036 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $179 | $200 | Not Implemented |
CO0036 # 03 Y:1985 | 03 | 1985 | REDESIGN PROCESS | $593 | $200 | Implemented |
CO0036 # 04 Y:1985 | 04 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,393 | $200 | Implemented |