Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,374
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0003 # 01 Y:2007 | 01 | 2007 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $65,640 | $16,926 | Not Implemented |
UA0003 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,585 | $54,205 | Not Implemented |
UA0003 # 03 Y:2007 | 03 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $43,286 | $20,950 | Not Implemented |
UA0003 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,528 | $0 | Not Implemented |
UA0003 # 05 Y:2007 | 05 | 2007 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,563 | $0 | Not Implemented |
UA0003 # 06 Y:2007 | 06 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,422 | $0 | Not Implemented |
UA0003 # 07 Y:2007 | 07 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $814 | $1,180 | Not Implemented |
UA0003 # 08 Y:2007 | 08 | 2007 | INSTALL OCCUPANCY SENSORS | $166 | $158 | Not Implemented |
UM0316 # 01 Y:2007 | 01 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,471 | $14,760 | Not Implemented |
UM0316 # 02 Y:2007 | 02 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,563 | $4,480 | Not Implemented |
UM0316 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,307 | $18,739 | Not Implemented |
UM0316 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $1,059 | $833 | Implemented |
UM0316 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $686 | $350 | Implemented |
UM0316 # 06 Y:2007 | 06 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $390 | $50 | Not Implemented |
NC0347 # 01 Y:2006 | 01 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $6,708 | $0 | Implemented |
NC0347 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,347 | $100 | Implemented |
NC0347 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,895 | $3,400 | Implemented |
NC0347 # 04 Y:2006 | 04 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,125 | $22,000 | Implemented |
NC0347 # 05 Y:2006 | 05 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,239 | $5,000 | Not Implemented |
NC0347 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $95 | $165 | Not Implemented |
NC0347 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,060 | $5,000 | Implemented |
NC0347 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $269 | $283 | Implemented |
GT0829 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,481 | $500 | Implemented |
GT0829 # 02 Y:2006 | 02 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $45,543 | $32,500 | Not Implemented |
GT0829 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,510 | $11,358 | Not Implemented |