Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,374
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0150 # 01 Y:1982 | 01 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $662 | $492 | Not Implemented |
TN0150 # 02 Y:1982 | 02 | 1982 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,328 | $0 | Not Implemented |
TN0150 # 03 Y:1982 | 03 | 1982 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $2,926 | $1,563 | Not Implemented |
TN0130 # 01 Y:1982 | 01 | 1982 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,419 | $3,500 | Not Implemented |
TN0130 # 02 Y:1982 | 02 | 1982 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $7,571 | $5,400 | Not Implemented |
TN0130 # 03 Y:1982 | 03 | 1982 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,269 | $1,000 | Not Implemented |
TN0130 # 04 Y:1982 | 04 | 1982 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,775 | $3,320 | Not Implemented |
UD0023 # 01 Y:1982 | 01 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $7,104 | $6,705 | Implemented |
UD0023 # 02 Y:1982 | 02 | 1982 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $14,006 | $3,864 | Implemented |
UD0023 # 03 Y:1982 | 03 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,266 | $300 | Implemented |
KU0025 # 01 Y:1981 | 01 | 1981 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $169 | $100 | Implemented |
KU0025 # 02 Y:1981 | 02 | 1981 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,267 | $1,200 | Not Implemented |
KU0025 # 03 Y:1981 | 03 | 1981 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $992 | $0 | Not Implemented |
KU0025 # 04 Y:1981 | 04 | 1981 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $685 | $2,076 | Not Implemented |
KU0025 # 05 Y:1981 | 05 | 1981 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,689 | $3,748 | Implemented |
KU0027 # 01 Y:1981 | 01 | 1981 | INSTALL AUTOMATIC STACK DAMPER | $1,605 | $1,800 | Not Implemented |
KU0027 # 02 Y:1981 | 02 | 1981 | INSTALL TIMERS AND/OR THERMOSTATS | $5,685 | $1,600 | Not Implemented |
KU0027 # 03 Y:1981 | 03 | 1981 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $700 | $0 | Not Implemented |
KU0027 # 04 Y:1981 | 04 | 1981 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $405 | $100 | Not Implemented |
KU0027 # 05 Y:1981 | 05 | 1981 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $200 | $0 | Not Implemented |
KU0027 # 06 Y:1981 | 06 | 1981 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $160 | $300 | Not Implemented |
KU0027 # 07 Y:1981 | 07 | 1981 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $185 | $0 | Not Implemented |
KU0027 # 08 Y:1981 | 08 | 1981 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,845 | $0 | Not Implemented |
KU0027 # 09 Y:1981 | 09 | 1981 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,720 | $5,466 | Not Implemented |