Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0353 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,709 | $16,548 | Not Implemented |
CO0353 # 02 Y:1996 | 02 | 1996 | REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER | $24,450 | $4,000 | Implemented |
CO0353 # 01 Y:1996 | 01 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $92,720 | $50,000 | Implemented |
CO0312 # 07 Y:1994 | 07 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $300 | $100 | Not Implemented |
CO0312 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,660 | $3,200 | Implemented |
CO0312 # 02 Y:1994 | 02 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $1,960 | $1,050 | Implemented |
CO0312 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,410 | $210 | Not Implemented |
CO0312 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $790 | $-290 | Implemented |
CO0312 # 05 Y:1994 | 05 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $500 | $150 | Not Implemented |
CO0312 # 06 Y:1994 | 06 | 1994 | INSULATE BARE EQUIPMENT | $380 | $320 | Implemented |
CO0036 # 11 Y:1985 | 11 | 1985 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $6,642 | $390 | Implemented |
CO0036 # 01 Y:1985 | 01 | 1985 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $179 | $0 | Implemented |
CO0036 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $179 | $200 | Not Implemented |
CO0036 # 03 Y:1985 | 03 | 1985 | REDESIGN PROCESS | $593 | $200 | Implemented |
CO0036 # 04 Y:1985 | 04 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,393 | $200 | Implemented |
CO0036 # 05 Y:1985 | 05 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,607 | $5,000 | Not Implemented |
CO0036 # 06 Y:1985 | 06 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,309 | $2,400 | Not Implemented |
CO0036 # 07 Y:1985 | 07 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,744 | $10,000 | Not Implemented |
CO0036 # 08 Y:1985 | 08 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $8,457 | $1,000 | Implemented |
CO0036 # 09 Y:1985 | 09 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,330 | $2,816 | Not Implemented |
CO0036 # 10 Y:1985 | 10 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $669 | $932 | Implemented |
CO0036 # 12 Y:1985 | 12 | 1985 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $750 | $340 | Not Implemented |
CO0010 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,635 | $0 | Implemented |
CO0010 # 11 Y:1984 | 11 | 1984 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $6,677 | $5,000 | Not Implemented |
CO0010 # 10 Y:1984 | 10 | 1984 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $769 | $130 | Implemented |